What's New
What's New contains a list of features and functionalities introduced in recent releases.
GigaVUE 6.2.xx Software offers usability improvements, resolved issues, and the new capabilities described below.
Online Documentation
|
Product Area |
Feature Summary |
Documentation ( |
||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
Next generation G-vTAP is a lightweight solution that acquires traffic from Virtual Machines and in-turn improves the performance of the G-vTAP Agent mirroring capability. The solution has a prefiltering capability at the tap level that reduces the traffic flow from the agent to V Series node and in-turn reduces the V Series load. Next generation G-vTAP Agent gets activated only on Linux system with a Kernel version above 5.4. |
GigaVUE Cloud Suite for AWS GigaVUE Cloud Suite for OpenStack Guide GigaVUE Cloud Suite for Azure Guide GigaVUE Cloud Suite for Third Party Orchestration |
||||||||||||||||||||
Use of Virtual machines as targets for VMware ESXi When creating maps for VMware ESXi in GigaVUE-FM, you can now select virtual machines as targets. You can view and filter the list of virtual machines available. You can also select the Network Adapters associated with each Virtual Machine. |
GigaVUE V Series GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
|||||||||||||||||||||
Cloud Overview Page The overview page is a central location to view and monitor all the monitoring sessions in a single place. You can use this overview page to spot issues which will help in troubleshooting, or perform basic actions like view, edit, clone, and delete. This page provides a quick overview of basic statistics, V Series Alarms, Connection Status and Volume Usage vs Allowance and a table to summarize the active monitoring sessions details. |
||||||||||||||||||||||
Support for Tapping Traffic from VLAN-Backed NSX Segments You can now monitor traffic from the virtual machines deployed in the VLAN-Backed NSX Segments in VMware NSX-T. |
||||||||||||||||||||||
Universal Container Tap (UCT): Traffic Policy Statistics
Rules are configured in the UCT to either forward the traffic to a Tunnel or drop the flow of the traffic. In the Policies page, along with the UCT policy and its rules, you can also view the aggregated statistics of all the source selectors which are part of the policy. The activities of the rules are reflected by the statistics counters. The statistics counters show how the policy statistics is directly cor-related to the policy and its rules configured through the GigaVUE-FM. |
Universal Container Tap Guide |
|||||||||||||||||||||
IPv6 support for GCB
The egress tunnel supports IPv4 and IPv6 address in Gigamon Containerized Broker (GCB). |
||||||||||||||||||||||
Support for Traffic Pre-filter in AWS If you want to filter the traffic, then you can create a traffic mirror filter on AWS and add rules to determine the traffic that is mirrored. This traffic mirror filter acts as a pre-filter and pass only the filtered traffic to the GigaVUE V Series Nodes. You can apply filters at two levels:
|
GigaVUE V Series
Configure a Traffic Pre-filter GigaVUE Cloud Suite for AWS |
|||||||||||||||||||||
Support for Gateway Load Balancer and Network Load balancer in Application Intelligence Solution Application Intelligence solution supports Gateway Load Balancer and Network Load balancer with VPC mirroring as the Traffic Acquisition Method. |
GigaVUE V Series
GigaVUE Cloud Suite for AWS |
|||||||||||||||||||||
Virtual Small Form Factor You can now monitor traffic in the branch office or the remote location using the GigaVUE-FM in the headquarters. Using a host hardware which has the VMware ESXi host deployed in it , you can deploy the GigaVUE V Series Nodes in it from the branch office and monitor it using the GigaVUE-FM in the Central location. |
GigaVUE Cloud Suite for Third Party Orchestration GigaVUE Cloud Suite for Third Party Orchestration |
|||||||||||||||||||||
Embedded |
User Configurable Tag Protocol Identifier (TPID) for VLAN Tagging With this feature you can now specify the Tag Protocol Identifier (TPID) for VLAN tagging while configuring the port depending on your requirements for the Inline/OOB tool. This includes the following TPID options
|
Fabric Management Configure Flexible Inline Flows GigaVUE Fabric Management Guide |
||||||||||||||||||||
Support for Resilient Inline Arrangement and Inline SSL in GigaVUE‑HC1-Plus The purpose of this feature is to Support for Resilient Inline Arrangement and Inline SSL in GigaVUE‑HC1-Plus |
Fabric Management Resilient Inline Arrangement with GigaSMART Flex Inline Solution GigaVUE Fabric Management Guide |
|||||||||||||||||||||
GigaVUE FM Core |
Disk Space Monitoring With the disk space monitoring feature, notification banners are displayed in the GigaVUE-FM GUI when disk space usage level exceeds a specific threshold limit thus alerting users immediately about the critical disk usage levels. Disk usage levels in all three partitions (/config, /var, /) of GigaVUE-FM is now monitored.
|
Fabric Management GigaVUE Fabric Management Guide |
||||||||||||||||||||
AMI Tool Templates The following new AMI tool templates are introduced in Application Metadata Intelligence. These tool templates are applicable for both physical and virtual devices.:
|
Fabric Management GigaVUE Fabric Management Guide |
|||||||||||||||||||||
Support for IPv6 Clustering You can configure the cluster topologies and perform cluster- related operations using IPv6 stacking. With this enhancement You can now:
|
Fabric Management Support for IPv6 Based Clustering GigaVUE Fabric Management Guide |
|||||||||||||||||||||
GigaSMART |
NetFlow License Check and Configuration Enablement in Application Intelligence On Gen3, NetFlow solution is provided by the Application Intelligence solution. This feature enables using the Application Intelligence solution for NetFlow configuration. The NetFlow app is supported from the App Intel solution by abstracting the device level implementation. The GigaVUE-FM GUI will display NetFlow as a new GSOP application when the NetFlow license is installed on the node. Here you can configure NetFlow with the pre-defined V5 template or V9 attributes. |
|||||||||||||||||||||
HC1 Gen3 iSSL with HSM and HC3 Gen3 iSSL with HSM The purpose of this feature is to provide the capability for inline-SSL feature to work with HSM (Hardware Security Module) hardware. Some enterprises where security is paramount use nCipher HSM to keep the sensitive information such as private keys safe. For the deployments that involves HSM, changes need to be done for how the keys are used during session establishment for inline-ssl feature.
|
Fabric Management GigaVUE Fabric Management Guide |
|||||||||||||||||||||
L3 Tools Support For HC1-Plus The L3 tools support is now available for GigaVUE-HC1-Plus. |
Fabric Management Configure Inline SSL Decryption Using GigaVUE‑FM GigaVUE Fabric Management Guide |
|||||||||||||||||||||
User-Defined Application Signature Support in Application Intelligence This feature improves customer experience by giving the ability to classify the applications that are not classified automatically by the DPI engine. The http, https, tcp, and, udp applications can be identified and named by using this feature. This feature is supported for both V series and H series. |
GigaVUE Fabric Management Guide | |||||||||||||||||||||
Uboot Update Notification for Gen 3 GS Card in Standalone Mode This feature blocks you from executing CLI commands when uboot update is in progress. You will get the following notification during bootup or card configuration. % GS Card uboot upgrade is happening. Cannot execute CLI command now You cannot execute any CLI command until the uboot update is complete or until a timer of 15 minutes expires |
Install U-Boot (If a Newer Version is Available) | |||||||||||||||||||||
iSSL Active /Standby Failover Improvement The following CLI commands is added to clear the session table entries: condition add PortRxPktLow param portId <port connected to active firewall> param thresh <minimum packet count> action add InlineSslFlushAll where InlineSslFlushAll action is used for clearing the session table entries. |
||||||||||||||||||||||
Support for IPv6 iSSL Decryption IPV6 iSSL decryption functionality is now supported for Generation 3 devices. |
Fabric Management Configure Flexible Inline SSL Decryption Solution GigaVUE Fabric Management Guide |
|||||||||||||||||||||
Hardware |
PRT-HC1-X12 Module A new line card PRT-HC1-X12 module provides a total 120Gb of connectivity with line rate on-board switching across twelve 10Gb/1Gb SFP/SFP+ ports. When two PRT-HC1-X12 modules are installed in the node, the GigaVUE-HC1-Plus provides twenty-four 10Gb/1Gb ports. |
Hardware GigaVUE-HC1-Plus Hardware Installation Guide |
||||||||||||||||||||
GigaVUE‑HC1 X-Port to Support 10/100M Speed The X ports of the GigaVUE-HC1 Base Chassis and PRT-HC1-Q04X08 module offer 10M/100M speed when 1 G copper optics are utilized. |
||||||||||||||||||||||
GigaVUE‑HC1-PlusOptics Qualification GigaVUE‑HC1-Plus supports optics from this release, version 6.2.00. |
GigaVUE-OS Compatibility and Interoperability Matrix | |||||||||||||||||||||
GigaVUE‑TA25EOptics Qualification
GigaVUE‑TA25E supports optics from this release, version 6.2.00. |
GigaVUE-OS Compatibility and Interoperability Matrix | |||||||||||||||||||||
Dual Rate 100/40G AOC Optics
CBL-505/510/550 Dual rate 100/40G AOC optics is now supported. |
GigaVUE-OS Compatibility and Interoperability Matrix | |||||||||||||||||||||
Licenses |
GigaVUE-OS and GigaVUE-OS Module Licenses GigaVUE-OS and GigaVUE-OS Module licenses can now be activated from the GigaVUE-FM GUI. Activation of licenses from GUI is applicable only for the GigaVUE HC Series devices and devices must be running software version 6.2.00 Appropriate banner notifications are displayed when the licenses expire.
|
Licensing |
||||||||||||||||||||
Documentation |
The following new guides are released:
|
|||||||||||||||||||||
GigaVUE 6.1.xx Software offers usability improvements, resolved issues, and the new capabilities described below.
Online Documentation
|
Product Area |
Feature Summary |
Documentation ( |
||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud
|
Traffic Health Monitoring GigaVUE-FM allows you to monitor the traffic health status of the entire monitoring session and also the individual GigaVUE V Series Nodes for which monitoring session is configured. Traffic health monitoring focuses on identifying any discrepancies (packet drop or overflow etc) in the traffic flow. When any such discrepancies are identified, GigaVUE-FM propagates the health status to corresponding monitoring session. |
Monitor Cloud Health | ||||||||||||||||||||||||
Header Stripping Application Header Stripping application efficiently examines the packets for specified headers like GTP, ISL, ERSPAN, MPLS, MPLS+VLAN, VLAN, VN-Tag, VXLAN, FM6000Ts, and generic and removes them before sending the packet to the appropriate security and analysis tools. Each packet is examined for the packet forwarding addition and it also ensured that the headers are removed from the packet before sending the packet to the tools. |
GigaVUE V Series Applications Guide |
|||||||||||||||||||||||||
5G-Service Based Interface Application
5G-Service Based Interface (SBI) Application synthesizes the HTTP2 transactions with proper L2, L3, and L4 headers from the JSON encoded data that it receives from the UDP-GRE or VXLAN ingress TEPs (Tunnel End Point). Once the headers are synthesized and a complete HTTP2 transaction is formed, the packets are sent to the egress TEP and then sent to the physical or virtual probes. The feature is supported on the following platforms:
|
5G-Service Based Interface Application | |||||||||||||||||||||||||
OVS Mirroring - IPv6 support
GigaVUE-FM supports mirror configuration using IPv6 which creates IPv6 tunnel to V Series node. |
Architecture of GigaVUE Cloud Suite for OpenStack | |||||||||||||||||||||||||
OVS Mirroring - SmartNIC offload From this release, OVS Mirroring is supported in Hardware offload. |
||||||||||||||||||||||||||
UCT: Bi-directional Rules In UCT, the source selector taps the traffic in both directions. |
||||||||||||||||||||||||||
UCT: Source Selector In UCT, the source selector supports the following addtional filter rules:
|
Configure UCT through GigaVUE-FM | |||||||||||||||||||||||||
UCT: Inventory Discovery In UCT, while creating a monitoring domain, there are following options to upload the inventory information:
|
||||||||||||||||||||||||||
Support for Gateway Load Balancers in AWS
You can now configure gateway load balancer endpoint as a target and the mirrored traffic can be forwarded from any subnet, AWS Virtual Private Cloud (VPC), or account in a highly scalable and operationally efficient manner to a GigaVUE V Series Node. The gateway load balancer endpoints are deployed in your subnets which contain the workloads. |
GigaVUE Cloud Suite for AWS–GigaVUE V Series 2 Configure a Gateway Load Balancer on GigaVUE Cloud Suite in AWS GigaVUE Cloud Suite for AWS–GigaVUE V Series 2 Guide |
|||||||||||||||||||||||||
Support for Third Party Orchestration
You can now configure GigaVUE Fabric Components like G-vTAP Controllers, G-vTAP Agents, and V Series Nodes using an external orchestrator. The deployed components will be available under Third Party Orchestration monitoring domain. |
GigaVUE Cloud Suite for Third Party Orchestration | |||||||||||||||||||||||||
Support to Configure AMI/AFI using Third Party Orchestration
You can use your own orchestration system to deploy GigaVUE V Series Nodes and then use GigaVUE‑FM to configure advanced features like Application Intelligence, Application Metadata Intelligence, and Application Filtering Intelligence |
GigaVUE Cloud Suite for Third Party Orchestration GigaVUE Cloud Suite for Third Party Orchestration |
|||||||||||||||||||||||||
Support for V Series 2 on GCP using Third Party Orchestration
You can now configure GigaVUE Fabric Components like G-vTAP Controllers, G-vTAP Agents, and V Series Nodes using Google Cloud Platform. The deployed fabric components can be monitored from GigaVUE-FM for traffic acquisition. |
GigaVUE Cloud Suite for Third Party Orchestration Configure GigaVUE Fabric Components in GCP GigaVUE Cloud Suite for Third Party Orchestration |
|||||||||||||||||||||||||
Support for V Series 2 on Nutanix using Third Party Orchestration
You can now configure GigaVUE Fabric Components like G-vTAP Controllers, G-vTAP Agents, and V Series Nodes using Nutanix Prism Central and also monitor the traffic in Nutanix VPC. The deployed fabric components can be monitored from GigaVUE-FM for traffic acquisition. |
GigaVUE Cloud Suite for Third Party Orchestration Configure GigaVUE Fabric Components in Nutanix GigaVUE Cloud Suite for Third Party Orchestration |
|||||||||||||||||||||||||
Support for V Series 2 on Nutanix This feature is replacing the existing GigaVUE-VM with V Series 2 node for better efficiency and accessibility on Nutanix environment. You can use De-dup and Load balancing applications in Monitoring Sessions |
GigaVUE Cloud Suite for Nutanix Guide |
|||||||||||||||||||||||||
New Fabric Components Version for 6.1.00
Fabric Components like G-vTAP Controllers, G-vTAP Agents, GigaVUE V Series Nodes, and GigaVUE V Series Proxy's version are now streamlined and they are in line with the GigaVUE-FM version. GigaVUE-FM version - 6.1.00 G-vTAP Controller - 6.1.00 G-vTAP Agent - 6.1.00 GigaVUE V Series Node - 6.1.00 GigaVUE V Series Proxy - 6.1.00 |
GigaVUE‑FM Version Compatibility Matrix GigaVUE V Series Quick Start Guide |
|||||||||||||||||||||||||
GigaVUE FM Core |
Manage Not-Reachable Nodes GigaVUE-FM can now manage the nodes that are not reachable by the cluster leader. The member nodes occasionally will not be reachable by the cluster leader if they have been deleted intentionally using CLI or if they are not-reachable due to power outage, crash or other similar reasons. GigaVUE-FM manages the not-reachable member nodes as part of the cluster and does not remove the nodes from the cluster, that is, GigaVUE-FM manages the not-reachable nodes in faulty/offline state. This allows easy management of the not-reachable nodes, especially in large deployment scenarios You can view the clusters with not-reachable nodes in the Physical Nodes page and in the Chassis page. |
Fabric Management Export Data to External Data Server GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
Traffic Drop Identification GigaVUE-FM periodically collects statistical data of the physical and logical resources from the devices. It is possible to detect significant traffic drop of a component using this historical data. The Traffic Drop Identification feature is implemented to detect the traffic drop at the decapsulation side of the tunnel. With this feature, you can create Alert Policies that binds the conditions and the resources required to identify the traffic drop. For software version 6.1.00, this feature is applicable for tunnel traffic drop identification. |
Fabric Management GigaVUE Administration Guide |
|||||||||||||||||||||||||
End-to-End Tunnel Monitoring The Tunnel Monitoring page provides a unified view of both ends of the tunnels created across the devices managed by GigaVUE-FM. GigaVUE-FM uses a tunnel discovery mechanism to identify the tunnels created across the managed nodes and clusters. The identified tunnels are logically grouped based on a specific grouping criteria and listed in the Tunnel Monitoring page. You can view the tunnel logical group statistics and also the health status of the components participating in the tunnel. You can also identify the traffic drop at the tunnels using the Traffic Drop Identification feature. |
Fabric Management GigaVUE Fabric Management Guide |
|||||||||||||||||||||||||
Improved Data Retention with Data Rollup With Data Rollup feature, GigaVUE-FM allows you to collect, summarize and display historical data for a period of 120 days with hourly granularity. Data Rollup is applicable only for Ports for this release. Rollup is enabled by default. Note: On upgrading to software version 6.1.00, ensure to increase the disk space for data rollup. |
Fabric Management GigaVUE-FM Statistics and Data Roll-up GigaVUE Fabric Management Guide |
|||||||||||||||||||||||||
Upload Images in GigaVUE-FM When upgrading GigaVUE-FM from the UI, you can upload only up to three images. If you try to upload a fourth image file, GigaVUE-FM removes the image file that was uploaded first based on timestamp and allows the fourth image file to upload successfully. |
Fabric Management Upgrade GigaVUE-FM from the UI GigaVUE Administration Guide |
|||||||||||||||||||||||||
GigaSMART |
Export Application Metadata Intelligence output in JSON format to Kafka
You can now use the Application Metadata Exporter (AMX) application to export AMI output in JSON format to Kafka. The AMX application converts the output from Application Metadata Intelligence (AMI) which is in CEF format into JSON format and sends it to Kafka. |
GigaVUE V Series Applications Guide |
||||||||||||||||||||||||
SCTP Protocol support for Application Filtering Intelligence GigaSMART Application Filtering Intelligence (AFI) feature matches network flows using rules configured on second-level map and forwards matching flow sessions to a chassis tool port and/or the next GigaSMART application in the chain. From 6.1 release, AFI supports sessions based on Layer4 protocol SCTP and all the protocols that run on top of SCTP. SCTP support for AFI is available on the following platforms:
|
Create Application Filtering Intelligence by Selecting Applications from Dashboard | |||||||||||||||||||||||||
Add source device and interface details to Netflow You can collect details on the switch management interface details discovery through network discovery and export the same using NetFlow feature. You can collect IPv4 or IPv6 switch management interface address by including additional collects in their configuration. This feature is currently supported in Generation 2 Legacy netflow CDP or LLDP process. |
Configuration Netflow Generation | |||||||||||||||||||||||||
GTP Rotational Sampling FM Stats You will have the ability to select the flow sampling type as "default" or "rotational", configure the timer, and the offset values during the creation and edition of Mobility solution. |
||||||||||||||||||||||||||
ISSL Qualification for HC1-Plus The SSL decryption for inline and out-of-band tools is now supported on GigaVUE-HC1-Plus. |
||||||||||||||||||||||||||
TLS decryption offload for Layer 3 tools This feature focuses on a new approach in GigaSMART to offload TLS decryption from Layer 3 inline-tools performing NAT / PAT (Network Address Translation / Port Address Translation) on the traffic passing through them. The GigaSMART engine would maintain two separate sessions towards the client and server-side to achieve this. |
||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
License |
Grace Period Behavior Gigamon offers a uniform grace period of 45 days from the day the license expires. During the grace period:
This grace period behavior is applicable for the following license types:
|
Licenses
GigaVUE Administration Guide |
||||||||||||||||||||||||
Documentation |
The following new guides are released:
|
|||||||||||||||||||||||||
GigaVUE 6.0 Software offers usability improvements, resolved issues, and the new capabilities described below.
New Features in 6.0.98 |
New Features in 6.0 |
Online Documentation
|
New Features in 6.0.98
Product Area |
Feature Summary |
Documentation ( |
---|---|---|
Hardware
|
New GigaVUE‑TA25E Device The GigaVUE‑TA25E is the latest member of the GigaVUE TA Series. It has a fixed module that supports ports of provides 48 25Gb/10Gb/1Gb ports ( x1...x48) and 8 100Gb/40Gb ports (c1..c8).
|
|
New GigaVUE‑TA200E Device The GigaVUE‑TA200E is the latest member of the GigaVUE TA Series. It has a fixed module that supports 64 100Gb/40 Gb ports.
|
||
New Features in 6.0
Product Area |
Feature Summary |
Documentation ( |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
Increase or Decrease Nodes in a Cluster for VMware NSX-T You can increase or decrease the number of V Series nodes in an existing monitoring domain when using Cluster-based deployments. |
GigaVUE Cloud Suite Configure GigaVUE V Series Nodes for VMware NSX-T GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
|||||||||||||||
Volume-Based Licensing Modifications The following details are newly added to the Volume-based licensing scheme:
|
GigaVUE Cloud Suite GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
||||||||||||||||
Support for Sharing the Same Host across Different Monitoring Domains in VMware You can deploy multiple GigaVUE V Series Nodes from VMware NSX-T monitoring domain and one V Series node from VMware ESXi monitoring domain on the same host. |
GigaVUE Cloud Suite Sharing the Same Host across Different Monitoring Domains Configure GigaVUE V Series Nodes for VMware NSX-T GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
||||||||||||||||
Universal Container Tap Universal Container Tap (UCT) is the new GigaVUE container tap that provides network traffic acquisition for containerized environments. Amazon EKS, Azure AKS, VMware Tanzu, Red Hat OpenShift, and native Kubernetes are the platforms supported for UCT. |
Universal Container Tap Universal Container Tap Guide |
||||||||||||||||
GigaVUE-VM to GigaVUE V Series Migration in VMware ESXi and NSX-V You can now migrate your GigaVUE-VM visibility solution to GigaVUE V Series visibility solution on VMware ESXi and NSX-V. Following are the two primary scenarios for GigaVUE V Series migration in GigaVUE-FM and in a GigaVUE-FM HA arrangement:
|
GigaVUE V Series Migration GigaVUE V Series Migration Guide |
||||||||||||||||
GCB Packet Reordering You can now use the packet reordering feature in your GCB solution to improve tool effectiveness. GCB waits for the pending packets from the requests and reorders the received packets to complete the transactions. |
Gigamon Containerized Broker Gigamon Containerized Broker Guide |
||||||||||||||||
Export Application Metadata Intelligence output in JSON format You can now use the Observability Gateway (OGW) application to export AMI output in JSON format. The OGW application converts the output from Application Metadata Intelligence (AMI) which is in CEF format into JSON format and sends it to cloud tools. |
Fabric Management Application Intelligence—Application Metadata Exporter GigaVUE Fabric Management Guide |
||||||||||||||||
Embedded
|
E-Tag Based Clustering Enhancements The below enhancements have been introduced in E-Tag based clustering such as:
|
Fabric Management GigaVUE Fabric Management Guide |
|||||||||||||||
GigaVUE FM Core |
Export Data to External Data Server GigaVUE-FM allows you to export statistical data from GigaVUE-FM to an external data server for analysis and visualization. The following data is exported from GigaVUE-FM (including the tags associated with the ports and maps) to an external data server:
|
Fabric Management Export Data to External Data Server GigaVUE Administration Guide |
|||||||||||||||
GigaStream Imbalance Notification With the GigaStream imbalance notification functionality, the port statistics of the member ports in a GigaStream are validated to determine if traffic distribution across the ports is within the allowed threshold limit based on a threshold value configured. If traffic distribution is not within the allowed variance limit, the GigaVUE HC series and TA series devices generate SNMP traps that are sent to GigaVUE-FM based on which GigaStream imbalance alarms are triggered. SNMP traps are generated in the devices based on the following conditions:
|
Fabric Management GigaStream Imbalance Notification GigaVUE Administration Guide |
||||||||||||||||
Fabric Health Analytics - Map Traffic Statistics The Fabric Health Analytics feature in GigaVUE‑FM is enhanced with the new Map Traffic Statistics dashboard that displays statistics about traffic that has passed/dropped through the fabric to the destination(s).
|
Fabric Management GigaVUE Fabric Management Guide |
||||||||||||||||
Topology Visualization The Topology page in GigaVUE-FM UI is enhanced as follows:
|
Fabric Management GigaVUE Fabric Management Guide |
||||||||||||||||
IP Resolver (Supporting Multiple Dynamic NIC) The IP Resolver page now allows you configure DNS server for more than one interface. This page has the following tabs:
|
Fabric Management GigaVUE Administration Guide |
||||||||||||||||
GigaSMART |
Supported Applications on Gen3 HC3 In SMT-HC3- C08 cards, the following GigaSMART applications are supported:
Supported Applications on Gen3 HC1 In SMT-HC1- S cards, the following GigaSMART applications are supported:
|
Fabric Management Guide |
|||||||||||||||
Vport Chaining within the same GigaSMART Group The transit-level maps support Application Filtering Intelligence (AFI) and Application Metadata Intelligence (AMI) GigaSMART operations in SMT-HC0-Q02X08 of HC2P, SMT-HC3-C05 of HC3v2, HC1-X12G4 of HC1 with native, SMT-HC3-C08, and SMT-HC1-S cards. |
Fabric Management Guide | ||||||||||||||||
GigaSMART GTP Rotational Sampling GTP Rotational Sampling samples GTP sessions by IMSI number, using a rotating or sliding IMSI range, that rotates automatically on a configurable interval, without disrupting the treatment of existing sessions. It rotates through the entire pool of subscribers over time, such that all subscribers can be sampled in over time
|
Fabric Management Guide | ||||||||||||||||
Hardware |
New GigaVUE-HC1-PLUS The GigaVUE-HC1- PLUS is the latest member of the GigaVUE HC Series. It has a fixed module that supports ports of 4 x 100G/40 G, 8x25G, 10G, and 1G connectivity in a 1RU form factor. It supports Flex-inline in unprotected ports with 100G/40G/10G/25G/10G/ speed. PRT-HC1-Q04, SMT-HC1-S, BPS-HC1-D25A60 and BPS-HC1-D35C60 modules are supported in GigaVUE-HC1-PLUS chassis. Note: Only Legacy PRT-HC1-Q04X08 and SMT-HC1-S modules are supported on GigaVUE-HC1-PLUS. The following features will not be supported with this release on GigaVUE-HC1-PLUS:
Refer to GigaVUE-OS Compatibility and Interoperability Matrix to view supported optics. |
GigaVUE-HC1-Plus Hardware Installation Guide | |||||||||||||||
New QSB 522 Transciever 100G/40G Dual Rate BiDi Transceiver Optic SKU QSB-522 is now supported. |
GigaVUE-OS Compatibility and Interoperability Matrix | ||||||||||||||||
Documentation |
New Guides The following three new guides are released:
|
||||||||||||||||
Serviceability Enhancements |
|
|
|||||||||||||||
GigaVUE 5.16.00 Software offers usability improvements, resolved issues, and the new capabilities described below.
Online Documentation
|
Product Area |
Feature Summary |
Documentation ( |
|||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
Proper handling of multiple AWS accounts in single deployment You can now monitor multiple AWS accounts or VPCs in a GigaVUE Cloud Suite for AWS monitoring domain. |
GigaVUE Cloud Suite for AWS GigaVUE Cloud Suite for AWS–GigaVUE V Series 2 Guide |
|||||||||||||||||||||||||||||||||||
Proper handling of multiple Azure subscriptions in single deployment You can now monitor multiple Azure subscriptions or tenants in a GigaVUE Cloud Suite for Azure monitoring domain. |
GigaVUE Cloud Suite for Azure GigaVUE Cloud Suite for Azure–GigaVUE V Series 2 Guide |
||||||||||||||||||||||||||||||||||||
OpenStack OVS Mirroring support for VLAN Trunk Port You can now use both access port and VLAN trunk port for the Open vSwitch (OVS) Mirroring on GigaVUE Cloud Suite for OpenStack. |
GigaVUE Cloud Suite for OpenStack GigaVUE Cloud Suite for OpenStack–GigaVUE V Series 2 Guide |
||||||||||||||||||||||||||||||||||||
GCB Transaction Logging You can now choose to create GCB transaction log files to determine the failed transactions. For each HTTPS POST message from Pcapper to GCB, the GCB creates a transaction record. The transaction record is logged to a transaction log file in the GCB pod or to the Kubernetes logging stdout stream. |
Gigamon Containerized Broker Gigamon Containerized Broker Guide |
||||||||||||||||||||||||||||||||||||
Cloud Health Monitoring GigaVUE-FM allows you to monitor the configuration health status of the entire monitoring session and also the individual fabric components for which monitoring session is configured. This feature provides detailed information about the configuration and deployment status of the deployed monitoring session. |
Fabric Management Cloud Health Monitoring - Configuration Health Monitoring GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
GigaVUE-FM HA on VMware NSX-T GigaVUE-FM HA can be deployed in VMware ESXi and managed in VMware NSX-T Manager to provide uninterrupted services to the customers. You must configure external IP address while forming the HA cluster. |
Fabric Management Configure GigaVUE‑FM High Availability in VMware NSX-T Manager GigaVUE Administration Guide |
||||||||||||||||||||||||||||||||||||
GigaVUE‑FM as image server for VMware NSX-T You can now upload your V Series Node image files into GigaVUE‑FM. Instead of using an external server to upload your image files you can now directly upload your OVA files into GigaVUE‑FM. |
GigaVUE Cloud Suite Upload GigaVUE V Series Node Image into GigaVUE-FM GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
||||||||||||||||||||||||||||||||||||
Embedded
|
Flexible Inline Arrangement is now supported in GigaVUE-TA25 Flexible Inline arrangement functionality is now supported in GigaVUE-TA25. Due to the absence of BPS module and GigaSMART card Physical Bypass and Inline SSL functionality will not be supported. The Inline Bypass Solution (Classic) is not supported in GigaVUE-TA25. |
GigaVUE Fabric Management Guide |
|||||||||||||||||||||||||||||||||||
E-Tag Based Clustering Clustering can now be configured based on E-Tags on GigaVUE-HC Series and GigaVUE-TA Series. You can select E-Tag based stacking mode to enable this feature. |
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
GigaVUE-FM Core
|
Configure PCAP from GigaVUE-FM You can now configure Packet Capture (PCAP) from GigaVUE-FM. The port type used for packet capture can be tool, network, hybrid, inline or inline network. Packet capture functionality is now extended for the following:
Packet Capture configuration is available from the Ports page. Refer to the GigaVUE-FM User's Guide for details. |
Fabric Management GigaVUE Fabric Management Guide |
|||||||||||||||||||||||||||||||||||
Delta Reports GigaVUE-FM provides support for generating delta reports for Flow Filtering reports. Delta reports display statistical data for a specific time interval from the current time. Use delta reports to troubleshoot the flow filtering behavior across two different timestamps. |
Fabric Management GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
Enhancements to Alarms Page - Alarm Drill down Few of the alarms listed in the alarms page are now configured with hyperlinks to the source that triggered the alarm thus providing a quick view of the alarm resource and the reason for failure. The source-ID field of the following alarm types are configured as hyperlinks which when clicked opens the quick view of the resource or navigates to the respective resource pages:
The following new alarms are generated in GigaVUE‑FM when the device is unreachable or when the report is not generated:
The child alarm Health Indeterminable is triggered along with the parent alarms and will be listed as a correlated alarm. |
Fabric Management GigaVUE Administration Guide |
||||||||||||||||||||||||||||||||||||
Fabric Health Analytics The Fabric Health Analytics feature in GigaVUE‑FM is enhanced with new dashboards and reports.
Fabric Asset Inventory: Displays inventory details of the devices managed by GigaVUE-FM and consists of the following data tables:
Fabric Health Dashboard now consists of two separate dashboards that display both metric and gauge visualizations.
The new Fabric Asset Inventory Report is added to the existing Reports list. Click on each of the items in the Report to navigate to the Discover page and to download the data tables in CSV format. |
Fabric Management GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
FIPS 140-2 Compliance in GigaVUE-FM GigaVUE-FM is now compliant with the Federal Information Processing Standard (FIPS), a US government standard for security requirements of cryptographic modules. You can enable FIPS from the Preferences page in GigaVUE-FM. Once enabled, you cannot disable it. You can also create a FIPS enabled HA group. Refer to the GigaVUE Administration Guide for details |
Fabric Management FIPS 140-2 Compliance in GigaVUE-FM GigaVUE Administration Guide |
||||||||||||||||||||||||||||||||||||
Application Metadata Intelligence
|
Allow for disable of AMI CEF multi-collect This feature enables the multi-collect of attributes within a given Metadata Store cache which means that if a configured attributes is seen in multiple packets within the same flow, each of these information is collected. By default, when a new cache is created, multi-collect is enabled. When upgraded from an older release, the multi-collect option is enabled. |
Fabric Management Guide Create Metadata Intelligence by Editing Monitoring Session from Dashboard |
|||||||||||||||||||||||||||||||||||
Advance-hash in Application Metadata Intelligence This feature configures metadata cache advance-hash for encapsulated flows . This feature improves the efficiency of scheduling the distribution of encapsulated flows. It also improves the distribution of flows in service provider deployment cases. By default, when a new cache is created, advance hash is enabled. When upgraded from an older release, the advance hash is enabled. |
Fabric Management Guide Create Metadata Intelligence by Editing Monitoring Session from Dashboard |
||||||||||||||||||||||||||||||||||||
AMI TEID Export on HC3 Gen3 In SMT-HC3-C08 cards, GigaSMART Application Metadata Intelligence supports the following packet attributes:
|
|||||||||||||||||||||||||||||||||||||
GigaSMART |
Supported Applications on Gen3 HC3 In SMT-HC3- C08 cards, the following GigaSMART applications are supported:
|
Fabric Management Guide |
|||||||||||||||||||||||||||||||||||
Vport Chaining within the same GigaSMART Group The transit-level maps supports multiple GigaSMART operations in SMT-HC0-Q02X08 of HC2P, SMT-HC3-C05 of HC3v2, HC1-X12G4 of HC1 with native, SMT-HC3-C08, and SMT-HC1-S cards.
|
Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
GTP JSON GTP Correlation engine can export records for each subscriber session. It only requires the GTP-C data to be input into the engine, and exports data in a streaming JSON format. This includes data such as subscriber ID, device ID, cell ID, session setup timestamp, and more. This data is used by metadata-ingestion tools.
|
Fabric Management Guide |
||||||||||||||||||||||||||||||||||||
Documentation |
GigaVUE-FM Hardware Appliance Guide for GFM-HW1-FM010 and GFM-HW1-FM001-HW This guide includes implementation information needed to get started with the GigaVUE-FM Hardware Appliance optimized module (GFM-HW1-FM001-HW) as a new, upgrading, or migrating customer.
|
GigaVUE-FM Hardware Appliance Guide for GFM-HW1-FM010 and GFM-HW1-FM001-HW |
|||||||||||||||||||||||||||||||||||
GigaVUE TA Series Hardware Installation Guide The GigaVUE TA Series Hardware Installation Guide is broken down and divided into the following guides:
|
|||||||||||||||||||||||||||||||||||||
GigaVUE 5.15.00 Software offers usability improvements, resolved issues, and the new capabilities described below.
Online Documentation
|
Product Area |
Feature Summary |
Documentation ( |
|||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
Support for V Series Node deployment using VMware NSX-T Manager You can now deploy V Series Nodes through VMware NSX-T Manager. The deployed V Series Node can be monitored from GigaVUE-FM for traffic acquisition, processing and forwarding. |
GigaVUE Cloud Suite for VMware Create Monitoring Domain for VMware NSX-T GigaVUE Cloud Suite for VMware—GigaVUE V Series Guide |
|||||||||||||||||||||||||||||||||
Supported GigaSMART operations on Microsoft Azure GigaVUE Cloud Suite for Azure support the following GigaSMART Application Intelligence operations.
|
GigaVUE Cloud Suite:
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||
Embedded |
Supported GigaSMART features on the 400G Link Traffic Aggregator The GigaVUE-TA400 product consists of a 1RU, rack-mountable, 32 x 400G QSFP-DD/QSFP28/QSFP+ ports, dual hot-pluggable AC/DC power supplies, seven hot swappable fan modules, a serial console port, and a 10M/100M/1G management port. The following features are supported in 5.15 release such as :
|
GigaVUE Fabric Management Guide
GigaVUE TA Series Hardware Installation Guide
|
|||||||||||||||||||||||||||||||||
GigaVUE-FM Core
|
Flow Ops Report Page Display Enhancement The GigaSMART Report page now displays the report type, GigaSMART Group and the Pattern selected for generating the FlowOps report in the header pane with the time stamp of when the report was generated. |
GigaVUE-FM
GigaVUE Fabric Management Guide |
|||||||||||||||||||||||||||||||||
Flow Filtering Reports Usability Enhancement GigaSMART Flow Filtering reports can now be generated as a single page. The links provided at the top of the report allows you to instantly navigate to the various sections in the report, thus eliminating excessive scrolling. The export button allows you to export the report in excel format with data captured in separate sheets for the different sections of the report. |
|||||||||||||||||||||||||||||||||||
API: /elasticUtils API The /elasticUtils API URL is now public and is available in the GigaVUE-FM swagger. |
GigaVUE-FM API
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||||||||||||
Documentation
|
GigaVUE-FM Hardware Appliance Guide for GFM-HW1-FM010
This guide includes implementation information needed to get started with the GigaVUE-FM Hardware Appliance as a new, upgrading, or migrating customer. |
GigaVUE-FM Hardware Appliance Guide for GFM-HW1-FM010 |
|||||||||||||||||||||||||||||||||
Command Line Summary This document summarizes the commands available in the command-line interface for the GigaVUE HC Series nodes. Commands are listed in alphabetical order with a summary of their syntax. |
GigaVUE-OS CLI Reference Guide: |
||||||||||||||||||||||||||||||||||
GigaVUE Cloud Suite for AWS The GigaVUE Cloud Suite for AWS Quick Start Guide is deprecated, and its contents are merged into the GigaVUE Cloud Suite for AWS Guide which is restructured and divided into the following two guides:
|
|
GigaVUE 5.14.00 Software offers usability improvements, resolved issues, and the new capabilities described below.
Online Documentation
|
Product Area |
Feature Summary |
Documentation ( |
|||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
Customer Orchestration of Traffic Acquisition for Azure You can now configure GigaVUE Cloud Suite components like G-vTAP Controllers, G-vTAP Agents, and V Series Nodes through an external orchestrator like Azure Portal. The deployed fabric components can be monitored from GigaVUE-FM for traffic acquisition, processing and forwarding. |
GigaVUE Cloud Suite for Azure Configure GigaVUE Fabric Components in Azure GigaVUE Cloud Suite for Azure Guide |
|||||||||||||||||||||||
GCB Log Level Settings With the GCB Log Level Setting, you can change the log level, modify the GCB log file size, and add miscellaneous log configuration messages for better logging and troubleshooting. |
Gigamon Containerized Broker View GCB Specifications in GigaVUE-FM Gigamon Containerized Broker Guide |
||||||||||||||||||||||||
Geneve decapsulation for AWS You can now choose the Geneve application from the GigaVUE Cloud Suite for AWS Monitoring Session canvas to acquire and strip Geneve headers. To route the traffic through the third-party network appliances seamlessly, the AWS gateway load balancer adds Geneve header to packets as they enter the VPC and strip these headers as the traffic leaves the VPC back into the servers. The third-party network appliances are expected to process traffic with these Geneve headers. When the GigaVUE-FM acquires the customer traffic, the packets are encapsulated in tunnels that are terminated in V Series nodes. |
GigaVUE Cloud Suite for AWS Add Applications to Monitoring Session GigaVUE Cloud Suite for AWS Guide |
||||||||||||||||||||||||
Cloud AMI/AFI Enhancements You can now deploy multiple GigaVUE V Series nodes in a solution and use V Series Node API Proxy Server (VPS) to scale and manage multiple V Series nodes. |
Resources for Configuring Solutions on GigaVUE V Series Nodes GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
Red Hat certification of GCB on OpenShift The GCB images are now "Red Hat Certified" for Red Hat OpenShift platform. |
Configure GCB for Service Mesh and HTTPS/2 Support with Metadata Gigamon Containerized Broker Guide |
||||||||||||||||||||||||
Supports AWS Outposts GigaVUE-FM now supports AWS Outposts. AWS Outposts is an on-premises extension of the AWS infrastructure, which allows you to make direct calls direct to AWS services (e.g., S3, EC2) from this solution. |
|||||||||||||||||||||||||
Embedded |
Flexible Inline Arrangement is now supported in GigaVUE-TA200 Flexible Inline arrangement functionality is now supported in GigaVUE-TA200. Due to the absence of BPS module and GigaSMART card Physical Bypass and Inline SSL functionality will not be supported. The Inline Bypass Solution(Classic)incompatibility remains same in GigaVUE-TA200.
|
GigaVUE Fabric Management Guide |
|||||||||||||||||||||||
Support Flexible Inline for Clustered GigaVUE HC Series Nodes The GigaVUE HC Series nodes that can be now clustered with Flexible Inline solution for the following Flexible Inline features: Resilient Inline Arrangement Network Link Aggregation Group (LAG) Asymmetrical Hashing |
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
Single Tag vs Double Tag VLAN mode for GigaVUE-TA25 GigaVUE-TA25 can now configure the VLAN tag mode to be single tag or double tag at the chassis level. Single tagged mode will be the preferred mode of operation when the deployment environment needs the visibility of just untagged and single-tagged packets.
|
GigaVUE Administration Guide
|
||||||||||||||||||||||||
GigaVUE-FM Core
|
Topology Visualization enhancements:
|
GigaVUE‑FM GigaVUE Fabric Management Guide GigaVUE Administration Guide |
|||||||||||||||||||||||
Fabric Health Analytics enhancements: New system dashboards and corresponding visualizations have been added:
Ability to navigate from FHA Alarms and Events dashboards to GigaVUE-FM Alarms and Events pages (with filters applied). |
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
Fabric Health Analytics for Cloud enhancements: New system dashboards and corresponding visualizations have been added:
Enhancement to existing dashboards with the addition of Aggregate Summary panel
|
GigaVUE‑FM Virtual Inventory Statistics and Cloud Applications Dashboard Dashboards for Volume-based Licenses Usage GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
Dynamic Increase in GigaVUE-FM HA Instances Until software version 5.13.00, GigaVUE-FM High Availability group was restricted to one active GigaVUE-FM instance and two standby GigaVUE-FM instances providing a scaled and resilient environment. As GigaVUE-FM is scaled up to manage many number of devices, higher computing and memory resources are required for the following reasons:
Therefore, the number of Elastic Search instances has to be increased in the HA group for scalable performance of the various features in GigaVUE-FM. GigaVUE-FM now allows you to add more than three GigaVUE-FM instances to the HA group. You can add any number of instances to the HA group as required. |
GigaVUE‑FM To add instances and to configure the HA group: GigaVUE Administration Guide |
||||||||||||||||||||||||
Port Packet Drop and Error Thresholds
|
GigaVUE‑FM GigaVUE Administration Guide |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
Alarm Suppression GigaVUE- FM allows you to suppress alarms that are raised during maintenance operation of a specific resource, cluster or node. You can suppress an alarm or alarms for a specific period or indefinitely by:
You can also configure auto-suppression of alarms for certain GigaVUE-FM triggered operations on device such as Configuration Restore, Device Reboot, Image Upgrade on a cluster or node., and Cluster Creation Operations. |
GigaVUE Administration Guide |
||||||||||||||||||||||||
Support SNMP Traps for GigaVUE-FM Alerts GigaVUE-FM sends SNMP v2c/v3 Trap notification for the GigaVUE-FM events such as Image Upgrade Status, Backup operation Status, etc., to the configured SNMP trap receivers. |
GigaVUE Administration Guide |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
GigaSMART
|
Optimized Elephant Flow processing for AFI Application Filtering Intelligence detects and handles the elephant flows in the traffic. The feature is supported on the following GigaSMART modules:
|
GigaVUE Fabric Management Guide |
|||||||||||||||||||||||
Supported Applications on Gen3 HC3 GigaSMART The following GigaSMART applications are supported on the new SMT-HC3- C08 module:
|
GigaVUE Fabric Management Guide |
||||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
Hardware |
New Gen3 HC3 GigaSMART Module The SMT-HC3-C08 module is the 3rd generation GigaVUE-HC3 GigaSMART module. This module is compatible only with Control Card version 2 (CCv2) and has two GigaSMART engines which have increased performance over the SMT-HC3-C05 module |
GigaVUE-HC3 Hardware Installation Guide |
|||||||||||||||||||||||
New 400G Link Traffic Aggregator The GigaVUE-TA400 product consists of a 1RU, rack-mountable, 32 x 400G QSFP-DD/QSFP28/QSFP+ ports, dual hot-pluggable AC/DC power supplies, seven hot swappable fan modules, a serial console port, and a 10M/100M/1G management port. The following features are not supported in 5.14 release such as :
|
GigaVUE TA Series Hardware Installation Guide |
||||||||||||||||||||||||
Documentation
|
Inclusive Language Initiative Gigamon is adopting inclusive language standards and is in the process of updating all of our content to remove exclusionary language wherever it exists, whether that be in Gigamon products and documentation, public-facing marketing materials, or internal communications. As we make these changes, we will announce updates to our terminology in our release notes and product documentation. For more information, refer to Inclusive Language Initiative. |
|
|||||||||||||||||||||||
Inline Bypass Solution (Classic) The Inline Bypass Solution (Classic) feature documentation will now be available only in earlier documents. Refer to Inline Bypass Solutions in GigaVUE Fabric Management Guide v5.13 or earlier. |
GigaVUE Fabric Management Guide v5.13 |
GigaVUE 5.13 Software offers usability improvements, resolved issues, and the new capabilities described below.
New Features in 6.0.98 |
New Features in 6.0 |
Online Documentation
|
New Features in 5.13.01
|
New Features in 5.13.00
Product Area |
Feature Summary |
Documentation ( |
|||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cloud |
V Series 2 on Azure This feature is replacing the existing V Series 1 node with V Series 2 node environments with optional V Series Proxy for better efficiency and accessibility on Azure platforms. With the V Series 2 based solution, you can create ingress tunnels, use public IP address types, and use all the V Series 2 supported GigaSMART applications in Monitoring Sessions. |
GigaVUE Cloud Suite for Azure:
|
|||||||||||||||||||||||||||||
OVS Mirroring for V Series 2 on OpenStack Now you can only select OVS Mirroring as your Traffic Acquisition Method for both OVS Mirroring and OVS Mirroring + DPDK. GigaVUE-FM can now auto detect and select the OVS Mirroring type required. |
GigaVUE Cloud Suite for OpenStack:
|
||||||||||||||||||||||||||||||
Service Identification on GCB In the Service mesh and HTTPS/2 supported platform, the Pcapper sends HTTPS/2 requests to GCB. On receiving the HTTPS/2 request from Pcapper, GCB applies the rules configured in GigaVUE-FM and forwards the filtered traffic to Tools or V Series 2 Nodes through L2GRE or VXLAN tunnels. These IP addresses of the Pcapper HTTPS/2 packets are temporary and the services running in multiple Kubernetes clusters can have same IP address. To correlate these ephemeral and same IP addresses, the GigaVUE-FM maps these ephemeral IP addresses with the corresponding source and destination CSV mapping files received from the Service Mesh and HTTPS/2 Supported platform and converts them to the external IPv6 addresses. |
Gigamon Containerized Broker for Service Mesh and HTTPS/2 Support with Metadata:
|
||||||||||||||||||||||||||||||
Dashboards for Cloud Statistics and Volume Based Licensing This enhancement introduces the following dashboards and the associated visualizations:
|
Fabric Management:
|
||||||||||||||||||||||||||||||
Cloud Enhancements |
Supported GigaSMART operations on AWS, OpenStack and VMware GigaVUE Cloud Suite for AWS and GigaVUE Cloud Suite for VMware support the following GigaSMART Application Intelligence operations in GigaVUE-FM version 5.13.00:
|
GigaVUE Cloud Suite:
|
|||||||||||||||||||||||||||||
Embedded | Enhanced Security
SHA1 support has been removed in 5.13.xx to improve security. Refer to Addendum in the Release Notes v5.13.xx for details. |
||||||||||||||||||||||||||||||
GigaVUE-FM Core |
Fabric Health Analytics BETA With Fabric Health Analytics, you can view the operational and health status of the various physical and virtual resources through the dashboards and visualizations. With this functionality you can:
The following new dashboards have been introduced:
|
Fabric Management:
|
|||||||||||||||||||||||||||||
Topology Visualization Beta The Topology Visualization Beta page allows you to create tagged layout topology. For smaller deployments, GigaVUE-FM creates Smart Layout Topology.This feature is enhanced as follows:
|
Fabric Management:
|
||||||||||||||||||||||||||||||
Bulk Tagging GigaVUE‑FM allows you to instantaneously,
Use the Import and Export Tags as Resources options in the Tags page to upload a CSV file containing the required fields. |
GigaVUE Administration:
|
||||||||||||||||||||||||||||||
Email Notifications The Email Notifications functionality is enhanced such that:
|
GigaVUE Administration:
|
||||||||||||||||||||||||||||||
GigaVUE-FM UI Reorg The GigaVUE‑FM GUI is enhanced as follows:
Note: Save Config option is removed from the top navigation bar and moved under the Chassis option
|
Fabric Management:
|
||||||||||||||||||||||||||||||
Rule-level Tagging You can now associate tags to map rules. Each rule within a map can be associated with different tags Ids and tag values. This is applicable for both flow maps and fabric maps. The Map Statistics dashboard includes visualizations that allows you to view the statistics of the flow of traffic at the rule level. |
Fabric Management:
|
||||||||||||||||||||||||||||||
GigaVUE‑FM Scale Enhancements Provides a reliable and stable environment for managing a large number of physical devices (up to 3000 devices) without any impact to the performance. The following changes are included as part of this release:
Note: Support for VIP in GigaVUE‑FM High Availability cluster is deprecated from software version 5.13.00. If there is VIP configured in GigaVUE‑FM < release 5.13.00, it will be continued after the upgrade. You will only be able to delete the existing VIP from software version 5.13. You cannot add or update the VIP.
|
GigaVUE Administration:
|
||||||||||||||||||||||||||||||
GigaVUE-FMEnhancements |
The GigaVUE-FM GUI is enhanced as follows:
These event-related updates will automatically get reflected in the respective pages. You can also use the Refresh button to view the Near-Real Time updates. |
Fabric Management and Administration:
|
|||||||||||||||||||||||||||||
GigaSMART Mobility
|
GigaSMART mobility session and flow filtering dashboards display flow filtering summary reports and statistics pertaining to the mobility solutions on an hourly, daily, weekly, or monthly interval. |
Fabric Management:
|
|||||||||||||||||||||||||||||
GigaVUE-OS |
Passive SSL Decryption with HSM Support on SMT-HC1-S (Early Access) The Generation 3 GigaSMART card (SMT-HC1-S), now supports Entrust nShield Hardware Security Module(HSM) integrated with Passive SSL decryption. Note: Early Access is a pre-GA feature status indicating it is not recommended for production networks. The functionality has been tested. Little to no system testing has been performed, however, and performance/scale data is not yet available. Preliminary documentation is available.
|
Fabric Management:
|
|||||||||||||||||||||||||||||
MAC Address Rewrite A user can now control or modify the Destination MAC and source MAC address of incoming traffic packets and deliver it to the tools according to the flow mapping configurations. |
Fabric Management:
|
||||||||||||||||||||||||||||||
Support Flexible Inline for Clustered GigaVUE HC Series Nodes The GigaVUE HC Series nodes can now be clustered with Flexible Inline solution for the configuration path. The traffic path is limited to a single node such that all inline network and tool ports should reside in the same node. The Flexible Inline features that can be configured are as follows:
|
Fabric Management:
|
||||||||||||||||||||||||||||||
Flexibility to Configure the PTP VLAN Range The PTP VLAN ID range has been increased to 2-4000. Hover on the help icon to identify the available VLAN ID resouce. |
Fabric Management:
|
||||||||||||||||||||||||||||||
Documentation |
The GigaVUE Cloud Suite for VMware Guide is now split into two separate guides:
|
Cloud:
|
|||||||||||||||||||||||||||||
|
Inclusive Language Initiative Gigamon is adopting inclusive language standards and is in the process of updating all of our content to remove exclusionary language wherever it exists, whether that be in Gigamon products and documentation, public-facing marketing materials, or internal communications. As we make these changes, we will announce updates to our terminology in our release notes and product documentation. For more information, refer to Inclusive Language Initiative. |
|
GigaVUE 5.12 Software offers usability improvements, resolved issues, and the new capabilities described below.
New in 5.12 Documentation
|
|
GigaVUE Software v5.11.00 offers usability improvements, resolved issues, and the following new capabilities.
New in 5.11 Documentation
|
Table 1: New feature reference table v5.11.00
|
GigaVUE Software v5.10.01 is the initial GA release of 5.10.xx. This release offers usability improvements, resolved issues, and the following new capabilities.
Prior to this release, GigaVUE-OS v5.10.00 was released as embed software on new hardware platforms, exclusively. For more about 5.10.00, see GigaVUE-OS on DELL S4112F-ON.
Table 2: New feature reference table v5.10.01
Area |
Feature |
Topic Link |
PDF Guide |
|||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Threat Detection |
SMT-HC1-S (GigaVUE-HC1 Gen 3 module with ThreatINSIGHT Sensor support) GigaVUE-HC1 supports a Generation 3 GigaSMART card (SMT-HC1-S), which gives 80Gb throughput and can be used to provide the ThreatINSIGHT solution for security detection. |
Hardware: |
GigaVUE-HC1 Hardware Installation Guide |
|||||||||||||||||||||||
Gigamon ThreatINSIGHT Sensor Gigamon ThreatINSIGHT is a SaaS-based network security monitoring platform built with the ability to detect, respond, and investigate network-based threats. You can also deploy Gigamon ThreatINSIGHT Sensor on the GigaVUE-HC1 SMT-HC1-S module using GigaVUE-FM. It provides single, integrated security solution for threat-detection. |
Fabric Management: Gigamon ThreatINSIGHT Sensor Fabric Management: |
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
Fabric Maps |
Fabric Port Group Extends GigaSMART load balancing functionality to fabric maps using circuit ids and circuit tunnels, thus allowing load balancing between tool ports that reside on different clusters. |
Fabric Management: Fabric Port Group |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
Flexible Inline Arrangement |
Resilient Inline Arrangement with Single VLAN Tag Deploy resilient inline arrangement with a single VLAN tag in which, a packet received from an inline network is guided to the inline tool using a single VLAN tag, which is configurable when creating a flexible inline map. |
Fabric Management: Configure Resilient Inline Arrangement |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
GigaVUE-OS |
Microburst Enhancements The Microburst performance in GigaVUE-OS devices have been improved such that devices have some amount of buffer to queue these packets. |
Fabric Management: Microburst |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
High and Low Utilization for GigaSMART Engine Ports GigaSMART engine ports now use high and low utilization threshold percentage. The utilization alarms will be forwarded to SNMP management stations configured as notification destinations. |
Fabric Management: Set Port Utilization Thresholds CLI Reference: portsnmp-server |
GigaVUE-FM User’s Guide GigaVUE-OS CLI Reference Guide |
||||||||||||||||||||||||
Port Filter Statistics Enhancements View the port filter counters based on the filter rules configured for the port. |
Fabric Management: Port Filters CLI Reference: port |
GigaVUE-FM User’s Guide GigaVUE-OS CLI Reference Guide |
||||||||||||||||||||||||
New Active Visibility Conditions and Actions for Inline Tool Groups You can now configure Active Visibility policies using conditions and actions that are newly added for inline tool group and flexible inline maps. |
Fabric Management: Configure Active Visibility CLI Reference: policy |
GigaVUE-FM User’s Guide GigaVUE-OS CLI Reference Guide |
||||||||||||||||||||||||
Intent-Based Orchestration |
Intent Based Orchestration Enhancements:
|
Fabric Management: Orchestrated Configurations |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
Mobility |
GigaSMART TCP Enhancements In 5G traffic, the GigaSMART TCP load balancing is performed based on the following correlations:
|
Fabric Management:
|
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
GigaSMART 5QI Correlation In 5G traffic, 5QI values present in the control traffic and its associated QoS Flow Identifiers (QFI) value are correlated and the data traffic is sent to the tools. |
Fabric Management: GigaSMART 5QI |
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
Enhanced Application Session Filtering (ASF) Enhanced Application Session Filtering allows to filter a specific application field from the incoming traffic. Enhanced Application Session Filtering supports the following session capabilities:
Netflow Cacheless export using TCP NetFlow monitor enables you to set the cache timeout to zero and makes the NetFlow to operate in a cacheless mode. Each packet received by the NetFlow is treated as a complete flow and the metadata extracted from the packet are immediately exported without caching the flow. In cacheless mode, the metadata are direclty sent to the export buffer as they are not copied to the cache, thereby providing more record space. |
|
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
GigaSMART Standalone User Plane Node Traffic Monitoring In Standalone User Processing Node (UPN) traffic monitoring, the UPN processes the subscriber information that is extracted from the Packet Forwarding Control Protocol (PFCP) packets and correlates with the GTP-u traffic without the CPN. |
Fabric Management: Stand-Alone User Plane Node Traffic Monitoring |
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
GigaSMART 5G Network Slice Correlation Network Slicing is a feature of 5G networks whereby slices of network resources are dedicated to a specific application. Gigamon enables customers to have differentiated levels of visibility for each network slice. |
Fabric Management: 5G Network Slice Correlation |
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
GigaSMART RAN Correlation This feature enables the support for RAN based correlation for both 4G CUPS and 5G CUPS solutions. The monitoring of core traffic is based upon the RAN source. It exposes RAN data fields from control plane. RAN data fields are available for filtering and whitelisting. |
Fabric Management: 5G RAN Correlation |
GigaVUE-FM User’s Guide |
||||||||||||||||||||||||
|
Enhancements to 5G CUPS Configuration using Ansible The Gigamon Ansible Module exposes playbooks that allows the configuration and maintenance of the CUPS solution, and the GigaVUE-FM GUI allows you to visualize, monitor and troubleshoot the CUPS solution. |
Fabric Management: Configuration of CUPS using Ansible. |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
FM Core |
Information Architecture and GUI Reorganization Improved and modernized user experience. Ease of accessibility of the physical and virtual nodes and the solutions. |
Fabric Management: |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
Alarms for Inline Networks and GigaSMART Operations Alarms to track the changes in the health status of the inline network configurations and the GigaSMART Operations.
|
Administration
|
GigaVUE-Administration Guide |
||||||||||||||||||||||||
GigaVUE-FM Scale Enhancements Provides a reliable and stable environment for managing large number of physical devices without any impact to the performance. Includes the following changes:
|
Fabric Management:
Administration:
|
GigaVUE-FM User’s Guide GigaVUE-Administration Guide |
||||||||||||||||||||||||
Security |
Protocol Signature Enhancements Upgrade the protocol signature by upgrading the image file on the card, and by uploading the GigaSMART card image to GigaVUE-FM from the Internal Server or External Server. |
Fabric Management: |
GigaVUE-FM User’s Guide |
|||||||||||||||||||||||
Software Licensing |
Volume based licensing for V Series on VMware Volume-Based License (VBL) is introduced to support V Series for VMware virtual device environments. In this model, instead of being assigned to a specific physical chassis or GigaSMART card, your license is based on the volume of data usage across many virtual devices gathered per available statistics collected in GigaVUE FM. Note: If you are using Volume Based Licensing, please make sure that smtp.gmail.com access on port 25 of the GigaVUE-FM host machine is not blocked by firewall ACL (Access Control List) rules or a proxy server. If it is blocked, it will prevent GigaVUE-FM from sending the mandatory emails regarding volume usage to Gigamon at the end of each collection period (normally 3 months). |
GigaVUE Cloud Suites: |
GigaVUE Cloud Suite Guides for AWS , OpenStack, and GCB |
|||||||||||||||||||||||
GigaSMART Security |
RFS Configuration to Manage Encrypted Keys Use Remote File System (RFS), a component in HSM to store and manage encrypted keys |
Fabric Management: Entrust nShield HSM for SSL Decryption for Out-of-Band Tools CLI Reference : |
GigaVUE-FM User’s Guide GigaVUE-OS CLI Reference Guide |
|||||||||||||||||||||||
Split DNS Profile Configuration for GigaSMART Engine Port Configure separate DNS servers for internal and external networks to ensure better security and privacy management |
CLI Reference:
|
GigaVUE-OS CLI Reference Guide |
||||||||||||||||||||||||
Cloud |
Network visibility with V Series nodes on VMware ESXi and NSX‑T This feature is replacing the existing GVMs with V Series 2 fabric node for better efficiency and accessibility on VMware environments. With the V Series based solution, users can create Monitoring Session instead of configuring vMaps and use Automatic Target Selection instead of manual vNIC selection in VMware ESXi and NSX-T. |
|
GigaVUE Cloud Suite for VMWare Configuration Guide |
|||||||||||||||||||||||
Gigamon Containerized Broker GCB Gigamon Containerized Broker (GCB) is a containerized packet broker component of Gigamon. GCB provides the network broker features in a containerized form for the customers who are running their workloads in containers. GCB can perform traffic acquisition, aggregation, basic filtering, replication, and tunneling with encryption support. |
Gigamon Containerized Broker Configuration Guide |
GigaVUE-OS 5.10.00 offers usability improvements, resolved issues, and the following new capabilities.
Table 3: New feature reference table v5.10.00
Product Area |
Feature |
Online Topic |
PDF Guide |
Ref |
---|---|---|---|---|
Software |
GigaVUE-OS on DELL S4112F-ON |
GigaVUE-OS on DELL S4112F-ON Installation Guide |
HD-57727 |
|
Hardware |
GigaVUE-TA25 |
GigaVUE-TA Series Hardware Installation Guide |
HD-56397 |
|
GTAP-A SF21 |
GigaVUE-OS CLI Reference: battery, battery optimization |
G-TAP A Series 2 Hardware Installation Guide: G-TAP GigaVUE-OS CLI Reference Guide: battery, battery optimization |
HD-58040 |
GigaVUE-OS on DELL S4112F-ON
The GigaVUE-OS is now installable on the commercial off-the-shelf (COTS) DELL S4112F-ON power switch. This integration allows the DELL S4112F-ON, with 12 1Gb/10Gb SFP+ and three 40Gb/100Gb QSFP28 ports, to run GigaVUE-OS with its core intelligence visibility node features and functionalities – all in a 1RU half rack-width form factor. Adding the Advanced Feature License enables clustering, tunneling, and header stripping.
(Reference: HD-57727)
Documentation: Refer to
GigaVUE-TA25
The GigaVUE-TA25 is the latest member of the GigaVUE-TA Series. It has 48 ports of 1/10/25Gb and 8 40/100Gb in a 1RU form factor. The Advanced Feature License enables clustering, tunneling, and header stripping.
(Reference: HD-56397)
Documentation: Refer to
G-TAP A Series 2
The G-TAP A Series 2 comprises active network taps that mirror 100% of network traffic, implement the “Always-On” architecture, and have increased density (8 TAPs in 1RU) and improved security (SSH and SNMPv3). This release introduces the following additional products in this series:
G-TAP-ASF21: The G-TAP A-SF2 SFP+ network TAPs run the same GigaVUE-OS as the GigaVUE TA Series and HC Series devices, and can be managed via CLI over SSH or by GigaVUE-FM. Unlike G-TAP A-TX2, the G-TAP A-SF21 supports SFP/SFP+ ports. |
G-TAP-ATX21-C: The G-TAP A-TX2 copper network TAPs run the same GigaVUE-OS as the GigaVUE TA Series and HC Series devices, and the G-TAP-ATX21 model can be managed via CLI over SSH or by GigaVUE-FM. The G-TAP-ATX21-C model looks and works just like G-TAP-ATX21 except the Ethernet management port is disabled and can only be managed via the console port. |
(Reference: HD-58040)
Documentation: Refer to