Example 3: Protected Inline Bypass Using Combo Modules
                                                            Example 3 is a protected inline bypass solution using bypass combo modules on GigaVUE‑HC3. It also configures heartbeat and negative heartbeat profiles.
                                                            Protected inline networks are based on the pairs of ports associated with the physical protection switches located on the bypass combo modules. Unlike the unprotected examples, you do not need to configure inline network ports because they are created automatically. On GigaVUE‑HC3, the port pairs are numbered for example: 2/2/x17 and 2/2/x18, 2/2/x19and 2/2/x20, 2/2/x21 and 2/2/x22, 2/2/x23 and 2/2/x24.
                                                            You do not need to configure inline networks because they are also created automatically on bypass combo modules. The aliases of the default inline networks are: default_inline_net_2_2_1, default_inline_net_2_2_2, default_inline_net_2_2_3, default_inline_net_2_2_4.
                                                            On GigaVUE‑HC3, protected inline bypass can be configured on the bypass combo module on ports c1..c4.
                                                            On GigaVUE‑HC1, protected inline bypass can be configured on the bypass combo module. It can also be configured on the TAP-HC1-G10040 module placed in either bay 2 or bay 3, so the ports will be 1/2/g1..g8 or 1/3/g1..g8. 
                                                            Note:  The default value of the physical-bypass attribute of protected inline networks is set to enable, which means that the fibers attached to ports net-a and net-b of the inline network are optically coupled and the traffic is exchanged between end nodes without coming to the switching fabric. of the GigaVUE node. As shown in Example 4, after configuring the inline tool and the map passall, the physical-bypass attribute is set to disable in order to activate the Inline Bypass solution.
                                                             
                                                            
                                                                
                                                                
                                                                
                                                                
                                                                    
                                                                        | 
                                                                             Task 
                                                                         | 
                                                                        
                                                                             Description 
                                                                         | 
                                                                        
                                                                             UI Steps 
                                                                         | 
                                                                    
                                                                
                                                                
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure inline too aliases, port type (inline-tool), and administratively enable inline network ports. 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    
        From the left navigation pane, go to System > Ports > Ports > All Ports. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Click Quick Port Editor. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    2. 
                                                                                     | 
                                                                                    Use Quick search to find the ports to configure. In this example, the ports are 2/2/x11 and 2/2/x12 | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    3. 
                                                                                     | 
                                                                                    Set port 2/2/x11 to Type Inline Tool and select Enable. Enter iT1 for the port alias. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    4. 
                                                                                     | 
                                                                                    Set port 2/2/x12 to Type Inline Tool and select Enable. Enter iT2 for the port alias. | 
                                                                                 
                                                                             
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure a heartbeat profile. 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline Bypass > Heartbeats. | 
                                                                                 
                                                                             
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    7. 
                                                                                     | 
                                                                                     In the Alias field, type hb2. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    8. 
                                                                                     | 
                                                                                    For Type, select Regular. | 
                                                                                 
                                                                             
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure negative heartbeat profile alias and PCAP file 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline Bypass > Heartbeats. | 
                                                                                 
                                                                             
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    11. 
                                                                                     | 
                                                                                    In the Alias field, type nhb1. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    12. 
                                                                                     | 
                                                                                    For Type, select Negative. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    13. 
                                                                                     | 
                                                                                    Click the Browse button for Custom Format and upload the pcap file; for example, hnb.pcap. | 
                                                                                 
                                                                             
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure inline tools, and enable them. Also specify the heartbeat profile. 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline Bypass > Inline Tools. | 
                                                                                 
                                                                             
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    16. 
                                                                                     | 
                                                                                     In the Alias field, type InTool1. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    17. 
                                                                                     | 
                                                                                    For Port A, select iT1. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    18. 
                                                                                     | 
                                                                                    For Port B, select iT2. | 
                                                                                 
                                                                             
                                                                            
                                                                            a. Select Enabled 
                                                                            b. Select Enabled Regular Heartbeat and set Profile to hb2. 
                                                                            c. Select Enabled Negative Heartbeat and set Negative Heartbeat Profile to nhb1. 
                                                                            
                                                                            Configure the second inline tool. 
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline Bypass > Inline Tools. | 
                                                                                 
                                                                             
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    22. 
                                                                                     | 
                                                                                     In the Alias field, type InTool2. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    23. 
                                                                                     | 
                                                                                    For Port A, select iT3. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    24. 
                                                                                     | 
                                                                                    For Port B, select iT4. | 
                                                                                 
                                                                             
                                                                            
                                                                            a. Select Enabled 
                                                                            b. Select Enabled Heartbeat and set Profile to hb_custom. 
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure the inline tool group and enable it. 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline Bypass > Inline Tool Group | 
                                                                                 
                                                                             
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    28. 
                                                                                     | 
                                                                                     In the Alias field, type inToolGroup. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    29. 
                                                                                     | 
                                                                                    For Inline Tools, select InTool1 and InTool2. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    30. 
                                                                                     | 
                                                                                    Under Configuration, select Enabled. | 
                                                                                 
                                                                             
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure map passall, from inline network to inline tool. 
                                                                         | 
                                                                        
                                                                            
                                                                            
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    33. 
                                                                                     | 
                                                                                    In the Alias field, type InMap. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    34. 
                                                                                     | 
                                                                                    Select Inline for Type and Pass All for Subtype. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    35. 
                                                                                     | 
                                                                                    For Source, select default_inline_net_2_2_1 | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    36. 
                                                                                     | 
                                                                                    For Destination, select InTool1 | 
                                                                                 
                                                                             
                                                                            
                                                                         | 
                                                                    
                                                                    
                                                                        | 
                                                                            
                                                                         | 
                                                                        
                                                                             Configure the path of the traffic to inline tool and disable the physical bypass 
                                                                         | 
                                                                        
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    1. 
                                                                                     | 
                                                                                    Select Inline ByPass > Inline Networks. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    38. 
                                                                                     | 
                                                                                    Select the Inline Network default_inline_net_2_2_1 and click Edit | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    39. 
                                                                                     | 
                                                                                    Under Configuration, set the Traffic Path field to To Inline Tool. | 
                                                                                 
                                                                             
                                                                            
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                     | 
                                                                                    40. 
                                                                                     | 
                                                                                    Make sure Physical Bypass is not selected. | 
                                                                                 
                                                                             
                                                                            
                                                                         |