Amazon VPC
You must have a Amazon Virtual Private Cloud (VPC) to launch GigaVUE Fabric Components into your virtual network. To create a VPC, refer to Create a VPC topic in the AWS Documentation.
Your VPC must have the following elements to configure the GigaVUE Cloud Suite for AWS:
Subnet for VPC
VPC must have a subnet to configure the GigaVUE Cloud Suite for AWS components. You can either have the components deployed in a single subnet or in multiple subnets.
- Management Subnet that GigaVUE-FM uses to communicate with the GigaVUE V Series Nodes and UCT-V Controllers.
- Data Subnet that can accept incoming mirrored traffic from agents or be used to egress traffic to a tool.
If a single subnet is used, then the Management subnet is also used as a Data Subnet
Security Group
When you launch GigaVUE‑FM, GigaVUE V Series Proxies, GigaVUE V Series Nodes, and UCT-V Controllers, a security group can be utilized to define virtual firewall rules for your instance, which in turn regulates inbound and outbound traffic. You can add rules to manage inbound traffic to instances, and a distinct set of rules to control outbound traffic.
To create a security group, refer to Create a security group topic in the AWS Documentation.
It is recommended to create a separate security group for each component using the rules and port numbers listed in the following table.
The following table lists the Network Firewall / Security Group requirements for GigaVUE Cloud Suite.
Note: When using dual stack network, the below mentioned ports must be opened for both IPv4 and IPv6.
GigaVUE‑FM |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
443 |
Administrator Subnet |
Allows GigaVUE-FM to accept Management connection using REST API. Allows users to access GigaVUE-FM UI securely through an HTTPS connection. |
||||||
Inbound |
TCP |
22 |
Administrator Subnet |
Allows CLI access to user-initiated management and diagnostics. |
||||||
Inbound (This is the port used for Third Party Orchestration) |
TCP |
443 |
UCT-V Controller IP |
Allows GigaVUE-FM to receive registration requests from UCT-V Controller using REST API. |
||||||
Inbound (This is the port used for Third Party Orchestration) |
TCP |
443 |
GigaVUE V Series Node IP |
Allows GigaVUE-FM to receive registration requests from GigaVUE V Series Node using REST API when GigaVUE V Series Proxy is not used. |
||||||
Inbound (This is the port used for Third Party Orchestration) |
TCP |
443 |
GigaVUE V Series Proxy IP |
Allows GigaVUE-FM to receive registration requests from GigaVUE V Series Proxy using REST API. |
||||||
Inbound |
TCP |
443 |
UCT-C Controller IP |
Allows GigaVUE-FM to receive registration requests from UCT-C Controller using REST API. |
||||||
Inbound |
TCP |
5671 |
GigaVUE V Series Node IP |
Allows GigaVUE‑FM to receive traffic health updates from GigaVUE V Series Nodes. |
||||||
Inbound |
TCP |
5671 |
UCT-V Controller IP |
Allows GigaVUE‑FM to receive statistics from UCT-V Controllers. |
||||||
Inbound |
TCP |
5671 |
UCT-C Controller IP |
Allows GigaVUE‑FM to receive statistics from UCT-C Controllers. |
||||||
Inbound |
UDP |
2056 |
GigaVUE V Series Node IP |
Allows GigaVUE‑FM to receive Application Intelligence and Application Visualization reports from GigaVUE V Series Node. |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound |
TCP |
9900 |
GigaVUE‑FM IP |
Allows GigaVUE‑FM to communicate control and management plane traffic with UCT-V Controller. |
||||||
Outbound (optional) |
TCP |
8890 |
GigaVUE V Series Proxy IP |
Allows GigaVUE‑FM to communicate control and management plane traffic to GigaVUE V Series Proxy. |
||||||
Outbound |
TCP |
8889 |
GigaVUE V Series Node IP |
Allows GigaVUE‑FM to communicate control and management plane traffic to GigaVUE V Series Node. |
||||||
Outbound |
TCP |
8443 (default) |
UCT-C Controller IP |
Allows GigaVUE‑FM to communicate control and management plane traffic to UCT-C Controller. |
||||||
Outbound |
TCP |
443 |
Any IP Address |
Allows GigaVUE‑FM to reach the Public Cloud Platform APIs. |
||||||
UCT-V Controller |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
9900 |
GigaVUE‑FM IP |
Allows UCT-V Controller to communicate control and management plane traffic with GigaVUE‑FM |
||||||
Inbound |
TCP |
9900 |
UCT-V or Subnet IP |
Allows UCT-V Controller to receive traffic health updates from UCT-V. |
||||||
Inbound (This is the port used for Third Party Orchestration) |
TCP |
8891 |
UCT-V or Subnet IP |
Allows UCT-V Controller to receive the registration requests from UCT-V. |
||||||
Inbound |
TCP |
22 |
Administrator Subnet |
Allows CLI access for user-initiated management and diagnostics, specifically when using third party orchestration. |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound (This is the port used for Third Party Orchestration) |
TCP |
443 |
GigaVUE‑FM IP |
Allows UCT-V Controller to send the registration requests to GigaVUE-FM using REST API. |
||||||
Outbound |
TCP |
9901 |
UCT-V Controller IP |
Allows UCT-V Controller to communicate control and management plane traffic with UCT-Vs. |
||||||
Outbound |
TCP |
5671 |
GigaVUE-FM IP |
Allows UCT-V Controller to send traffic health updates to GigaVUE‑FM. |
||||||
UCT-V |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
9901 |
UCT-V Controller IP |
Allows UCT-V to receive control and management plane traffic from UCT-V Controller |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound (This is the port used for Third Party Orchestration) |
TCP |
8891 |
UCT-V Controller IP |
Allows UCT-V to communicate with UCT-V Controller for registration and Heartbeat |
||||||
Outbound |
UDP (VXLAN) |
VXLAN (default 4789) |
GigaVUE V Series Node IP |
Allows UCT-V to tunnel VXLAN traffic to GigaVUE V Series Nodes |
||||||
Outbound |
IP Protocol (L2GRE) |
L2GRE (IP 47) |
GigaVUE V Series Node IP |
Allows UCT-V to tunnel L2GRE traffic to GigaVUE V Series Nodes |
||||||
Outbound (Optional - This port is used only for Secure Tunnels) |
TCP |
11443 |
GigaVUE V Series Node IP |
Allows UCT-V to securely transfer the traffic to the GigaVUE V Series Node |
||||||
Outbound |
TCP |
9900 |
UCT-V Controller IP |
Allows UCT-V to send traffic health updates to UCT-V Controller. |
||||||
GigaVUE V Series Node |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
8889 |
GigaVUE-FM IP |
Allows GigaVUE V Series Node to communicate control and management plane traffic with GigaVUE-FM |
||||||
Inbound |
TCP |
8889 |
GigaVUE V Series Proxy IP |
Allows GigaVUE V Series Node to communicate control and management plane traffic with GigaVUE V Series Proxy. |
||||||
Inbound |
UDP (VXLAN) |
VXLAN (default 4789) |
UCT-V Subnet IP |
Allows GigaVUE V Series Nodes to receive VXLAN tunnel traffic to UCT-V |
||||||
Inbound |
IP Protocol (L2GRE) |
L2GRE |
UCT-V Subnet IP |
Allows GigaVUE V Series Nodes to receive L2GRE tunnel traffic to UCT-V |
||||||
Inbound |
UDPGRE |
4754 |
Ingress Tunnel |
Allows GigaVUE V Series Node to receive tunnel traffic from UDPGRE Tunnel |
||||||
Inbound |
TCP |
22 |
Administrator Subnet |
Allows CLI access for user-initiated management and diagnostics, specifically when using third party orchestration. |
||||||
Inbound (Optional - This port is used only for Secure Tunnels) |
TCP |
11443 |
UCT-V subnet |
Allows to securely transfer the traffic to GigaVUE V Series Nodes. |
||||||
Inbound (Optional - This port is used only for configuring AWS Gateway Load Balancer) |
UDP (GENEVE) |
6081 |
Ingress Tunnel |
Allows GigaVUE V Series Node to receive tunnel traffic from AWS Gateway Load Balancer. |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound |
TCP |
5671 |
GigaVUE-FM IP |
Allows GigaVUE V Series Node to send traffic health updates to GigaVUE‑FM. |
||||||
Outbound |
UDP (VXLAN) |
VXLAN (default 4789) |
Tool IP |
Allows GigaVUE V Series Node to tunnel output to the tool. |
||||||
Outbound |
IP Protocol (L2GRE) |
L2GRE (IP 47) |
Tool IP |
Allows GigaVUE V Series Node to tunnel output to the tool. |
||||||
Outbound |
UDP |
2056 |
GigaVUE-FM IP |
Allows GigaVUE V Series Node to send Application Intelligence and Application Visualization reports to GigaVUE-FM. |
||||||
Outbound |
UDP |
2055 |
Tool IP |
Allows GigaVUE V Series Node to send NetFlow Generation traffic to an external tool. |
||||||
Outbound |
UDP |
514 |
Tool IP |
Allows GigaVUE V Series Node to send Application Metadata Intelligence log messages to external tools. |
||||||
Bidirectional (optional) |
ICMP |
|
Tool IP |
Allows GigaVUE V Series Node to send health check tunnel destination traffic. |
||||||
Outbound (This is the port used for Third Party Orchestration) |
TCP |
8891 |
GigaVUE V Series Proxy IP |
Allows GigaVUE V Series Node to send registration requests and heartbeat messages to GigaVUE V Series Proxy when GigaVUE V Series Proxy is used. |
||||||
Outbound (This is the port used for Third Party Orchestration) |
TCP |
443 |
GigaVUE-FM IP |
Allows GigaVUE V Series Node to send registration requests and heartbeat messages to GigaVUE-FM when GigaVUE V Series Proxy is not used. |
||||||
Outbound (Optional - This port is used only for Secure Tunnels) |
TCP |
11443 |
Tool IP |
Allows to securely transfer the traffic to an external tool. |
||||||
GigaVUE V Series Proxy (optional) |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
8890 |
GigaVUE‑FM IP |
Allows GigaVUE‑FM to communicate control and management plane traffic with GigaVUE V Series Proxy. |
||||||
Inbound (This is the port used for Third Party Orchestration) |
TCP |
8891 |
GigaVUE V Series Node IP |
Allows GigaVUE V Series Proxy to receive registration requests and heartbeat messages from GigaVUE V Series Node. |
||||||
Inbound |
TCP |
22 |
Administrator Subnet |
Allows CLI access for user-initiated management and diagnostics, specifically when using third party orchestration. |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound |
TCP |
443 |
GigaVUE-FM IP |
Allows GigaVUE V Series Proxy to communicate the registration requests to GigaVUE-FM |
||||||
Outbound |
TCP |
8889 |
GigaVUE V Series Node IP |
Allows GigaVUE V Series Proxy to communicate control and management plane traffic with GigaVUE V Series Node |
||||||
Universal Cloud Tap - Container deployed inside Kubernetes worker node |
||||||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound |
TCP |
42042 |
Any IP address |
Allows UCT-C to send statistical information to UCT-C Controller. |
||||||
Outbound |
UDP |
VXLAN (default 4789) |
Any IP address |
Allows UCT-C to tunnel traffic to the GigaVUE V Series Node or other destination. |
||||||
UCT-C Controller deployed inside Kubernetes worker node |
||||||||||
Direction |
Protocol |
Port |
Source CIDR |
Purpose |
||||||
Inbound |
TCP |
8443 (configurable) |
GigaVUE-FM IP |
Allows GigaVUE-FM to communicate with UCT-C Controller. |
||||||
Direction |
Protocol |
Port |
Destination CIDR |
Purpose |
||||||
Outbound |
TCP |
5671 |
Any IP address |
Allows UCT-C Controller to send statistics to GigaVUE-FM. |
||||||
Outbound |
TCP |
443 |
GigaVUE-FM IP |
Allows UCT-C Controller to communicate with GigaVUE-FM. |