Removing the Control Card
The GigaVUE‑HC3 control card is located behind the fan tray in the rear of the chassis. It is field-replaceable. Since there is only one internal control card , the node must be powered down. Hot swapping is not possible.
To remove the control card:
- If the node is powered on, log in to the serial console port on the node and power it down gracefully with the reload halt command.
- Power down the node by unplugging the power cable.
- Remove the fan tray as described in Removing a Fan Tray. The control card is located behind the fan tray, as shown in 1 Control Card Location.
1 | Control Card Location |
- Swing both ejector handles outward, as shown in 2 Control Card Ejector Handles.
2 | Control Card Ejector Handles |
- Pull out the control card. Refer to 3 Control Card Removal.
3 | Control Card Removal |
For procedures to replace a control card, refer to Replacing Control Card. There are separate procedures for standalone nodes, nodes in an out-of-band cluster, and nodes in an inband cluster.
To insert the control card, refer to Inserting the Control Card.