Prerequisites for Integrating GigaVUE V Series Nodes with vCenter
This section describes the requirements and prerequisites for configuring the vCenter. Refer to the following section for details.
- Network Firewall Requirements for ESXi
- Recommended Instance Types for ESXi
- Required VMware Virtual Center Privileges
Note: To support internationalized characters in the VMware vCenter environment ensure that the vCenter character encoding is set to UTF-8.
Network Firewall Requirements for ESXi
Following are the Network Firewall Requirements for GigaVUE V Series Node deployment.
Source | Destination | Source Port | Destination Port | Protocol | Service | Purpose |
GigaVUE-FM |
ESXi hosts |
Any (1024-65535) |
443 |
TCP |
https |
Allows GigaVUE‑FM to communicate with vCenter and all ESXi hosts to import the V Series OVA files. OVA files require access to the host IP/URL for bulk deployment |
vCenter |
||||||
GigaVUE-FM |
GigaVUE V Series Nodes |
Any (1024-65535) |
8889 |
TCP |
Custom API |
Allows GigaVUE‑FM to communicate with GigaVUE V Series Node |
GigaVUE-FM |
GigaVUE V Series Nodes |
Any (1024-65535) |
5671 |
TCP |
Custom TCP |
Allows GigaVUE-FM to receive the traffic health updates with GigaVUE V Series Node |
Administrator |
GigaVUE-FM |
Any (1024-65535) |
443 |
TCP |
https |
Management connection to GigaVUE‑FM |
22 |
ssh |
|||||
Administrator |
GigaVUE V Series Nodes |
Not Applicable |
22 |
|
ssh |
Troubleshooting GigaVUE V Series Nodes. |
Remote Source |
GigaVUE V Series Nodes |
Custom Port(VXLAN and UDPGRE),N/A for GRE |
4789 |
UDP |
VXLAN |
Allows to UDPGRE Tunnel to communicate and tunnel traffic to GigaVUE V Series Nodes (Applicable for Tunnel Ingress option only) |
N/A |
IP 47 |
GRE |
||||
4754 |
UDP |
UDPGRE |
||||
GigaVUE V Series Nodes |
Tool/ GiagVUE HC Series instance |
Custom Port(VXLAN),N/A for GRE |
4789 |
UDP |
VXLAN |
Allows GigaVUE V Series Node to communicate and tunnel traffic to the Tool |
Not Applicable |
IP 47 |
GRE |
||||
GigaVUE V Series Nodes |
Tool/ GigaVUE HC Series instance |
Not Applicable |
Not Applicable |
ICMP |
Echo Request |
Allows GigaVUE V Series Node to health check tunnel destination traffic (Optional) |
Echo Response |
||||||
GigaVUE V Series Nodes |
GigaVUE-FM |
Any (1024-65535) |
Any (1024-65535) |
TCP |
Custom TCP |
Allows GigaVUE V Series Nodes to communicate the traffic health updates with GigaVUE‑FM |
Recommended Instance Types for ESXi
The instance size of the V Series is configured on the OVF file and packaged as part of the OVA image file. The following table lists the available instance types and sizes based on memory and the number of vCPUs for a single V Series node. Instances sizes can be different for V Series nodes in different ESXi hosts and the default size is Small.
Type |
Memory |
vCPU |
Disk space |
vNIC |
---|---|---|---|---|
Small |
4GB |
2 vCPU |
8GB |
1 Management interface, 1 Tunnel interface, and 8 vTAP interfaces |
Medium |
8GB |
4 vCPU |
||
Large |
16GB |
8 vCPU |
Note: Refer to Support, Sales, or Professional Services for deployment optimization.
Required VMware Virtual Center Privileges
This section lists the minimum privileges required for the GigaVUE‑FM user in Virtual Center. You assign privileges to Virtual Center users by selecting Administration from the left navigation pane. Then select Roles under the Access Control. Roles should be applied at the vSphere Virtual Center level and not the Data Center or Host levels.
The following table lists the minimum required permissions for GigaVUE‑FM to manage the virtual center user with roles specified above.
Category |
Required Privilege |
Purpose |
|||||||||
Datastore |
Allocate space |
V Series Node Deployment |
|||||||||
Distributed Switch |
VSPAN Operation |
VDS Tapping |
|||||||||
Folder |
Create Folder |
V Series Node Deployment |
|||||||||
Host |
Configuration
|
VSS Tapping |
|||||||||
Inventory
|
Pin V Series Node to the host in cluster configurations. This prevents automatic migration. |
||||||||||
Network |
|
|
|||||||||
Resource |
Assign virtual machine to resource pool |
V Series Node Deployment |
|||||||||
vApp |
|
V Series Node Deployment |
|||||||||
Virtual machine |
Configuration
|
V Series Node Deployment V Series Node Deployment/VSS Tapping |
|||||||||
Interaction
|
V Series Node Deployment |
||||||||||
Inventory
|
V Series Node Deployment |
||||||||||
Provisioning
|
V Series Node Deployment |