reset

Required Command-Line Mode = Configure

Required User Level = Admin

Use the reset command to return the GigaVUE® HC Series node to factory settings.

The reset command has the following syntax:

reset factory <all | keep-all-config | only-traffic>

The system is rebooted after the process completes.

Note:  Starting in software release 5.2 on the GigaVUE-HB1 node, issue the card all or card slot 1 command to bring up the chassis, especially after configuring it for the first time, or after issuing the reset factory all command.

Note:  To halt the system, use reload halt. Refer to reload (reboot).

The following table describes the arguments for the reset command:

Command

Description

factory <all | keep-all-config | only-traffic>

Specifies the portions of the system configuration to reset to factory defaults:

all—Resets all configuration files, configuration text files, backtrace files, and temporary files.
keep-all-config—Preserves all configuration files, but clears all log files and temporary files from the system. Note that this command does not affect any configuration settings.
only-traffic—Resets only chassis, cards, and traffic configuration. System configuration settings are preserved.

Note:  The reset factory only-traffic command reloads the node without issuing the reload command.

Examples:

(config) # reset factory all

(config) # reset factory keep-all-config

(config) # reset factory only-traffic

Note:  Using reset factory deletes passwords on user accounts. When you login with the admin account, you will be prompted for a new password through the jump-start script.