Connecting Power to the GigaVUE‑HC1-Plus
The GigaVUE‑HC1-Plus supports AC and DC power in a 1+1 redundant configuration. In all cases, only a single power supply module is required to operate the node. However, connecting both modules in a 1+1 configuration provides redundant power.
Note: It is recommended not to insert different product codes PSU in the same chassis. Doing so will give an SNMP mismatch trap. For example, PSU PWR-TAC21 and PWR-HC1P1, PWR-TAC22 and PWR-HC1P2 must not co-exist in PSU slots; PSU AC/DC and PSU DC/DC must not co-exist in PSU slots.
The procedure for connecting power to the GigaVUE‑HC1-Plus is similar to the other GigaVUE H Series nodes:
GigaVUE Chassis Type |
Number of Power Supply Modules |
GigaVUE‑HC1-Plus |
2 |
- Plug an approved C13 power cable into each of the power supply modules at the rear of the GigaVUE‑HC1-Plus chassis.
Note: For information about connecting the optional DC power supply modules, refer to Connecting DC Power Supply Module.
1 | Connecting AC Power (GigaVUE‑HC1-Plus) |
- Plug the other end of the power cables into a power source that can supply adequate power. For optimal power protection, plug the power supply modules into separate circuits. When connecting to the external AC power source, ensure that a Surge Protective Device (SPD) is installed at the AC power inlet. For information aboutGigaVUE‑HC1-Plus power requirements, refer to AC- and DC-Powered GigaVUE‑HC1-Plus.
Note: To avoid disk corruption, please ensure the "reload halt" command is executed before an ungraceful power shutdown or power supply module removal.
-
Power is turned ON when the unit is plugged in, and turned off when the unit is unplugged. To remove a power supply module, refer to Removing a Power Supply Module.
-
Once the power supply is turned OFF, wait for 1 minute (60 seconds) before turning the power supply ON for GigaVUE‑HC1-Plus.