show

Required Command-Line Mode = Standard

Use the show command to view configuration and status information for GigaVUE‑OS nodes. Configuration commands in the CLI have corresponding show commands that display the configured values and the current status.

To match a keyword or a regular expression in the show command, use the option matching <regex> after the show command. You should type the keyword completely as the auto-fill option is not supported for the keyword. The command has the following syntax;

show <command> matching <regex>

<regex> is the regular expression to be used as a filter.

For example:

Example 1
show port params matching SFP
 
Example 2
show chassis matching down
 
Example 3
show running-config matching apps
 

Note:  For the following three commands, matching option is not available:
show cli history matching
show diag matching
show system matching

The device does not cancel an operation when <CTRL+C> is given after a show command instead the Command Line Interface shows an error message. In stand-alone devices, no other command should be issued after the <CTRL+C> command. You can use either of the workaround:

■   Reboot the device from the GigaVUE-FM
■   Exit from the CLI session and then re-log

The following table describes the show commands:

Show Command

Description

show aaa
show aaa authentication attempts
show aaa authentication attempts
configured
show aaa authentication attempts status [user    <username>]
show aaa authentication certificate crl name default

For usage examples, refer to aaa accounting, aaa authentication, and aaa authorization.

show action [alias <alias> | detail]

For usage examples, refer to policy.

box <box ID> [brief] | brief | slot <slot ID> [brief]]

For usage examples, refer to filter-template.

show apps

 

show apps <asf | enhanced -asf | enhanced- lb | enhanced-slicing | exporter | gtp-whitelist | hsm | hsm-group | inline-ssl | keystore | listener | metadata | netflow | port-throttle | regex-profile | sip-whitelist | split-dms | ssl>

 

show apps asf <alias <alias> | all | stats> <alias <alias> | all>

For usage examples, refer to apps asf

show apps enhanced-asf <alias <alias> | all | stats> <alias <alias> | all>

show apps enhanced-lb <alias <alias> | all>>

For usage examples, refer to apps enhanced asf..

show apps enhanced-slicing <alias <alias> | all | stats>

For usage examples, refer to apps enhanced-slicing.

show apps exporter alias <alias>

For usage examples, refer to apps exporter.

show apps gtp-whitelist alias <alias> count

For usage examples, refer to apps gtp-whitelist.

show apps hsm <alias <alias> | all>>

For usage examples, refer to apps hsm.

show apps hsm-group <anonkneti | enquiry | chkserv | ckinfo | key | world | config | module | session-stats | buffer-stats | all | status>

 

For usage examples, refer to apps hsm-group.

show apps inline-ssl
   caching
      certificate validation <certificate CN | status>
      url <domain name | status>
   global
   monitor <session <any | match <ipv4-dst <IP
     address | mask> | ipv4-src | <IP address | mask>

<ipv6-dst <IPv6 address | mask> | ipv6-src |

 <IPv6 address | mask>l4port-dst <L4port | any> |
      l4port-src <L4port |any>>> | summary>
   profile <alias <alias> [decryptlist | nodecryptlist]
      <domain name> | all>
   session
      any
      debug vport <vport alias>
      match ipv4-src <IP addr/mask> ipv4-dst <IP addr/
       mask> ipv6-src <IPv6 addr/mask> ipv6-dst

<IPv6 addr/mask> l4port-src <port number> l4port-dst <portnumber> [detail] | hostname <hostname>
      summary
   trust-store <all | certificate fingerprint <fingerprint string>>

For usage examples, refer to apps inline-ssl.

 

 

Debug is reserved for internal use.

 

Note:  IPV6 traffic decryption is supported only for GEN 3 cards. Refer to the GigaVUE-HC1 Hardware Installation Guide and GigaVUE-HC3 Hardware Installation Guide for the list of GEN 3 card numbers.

show apps keystore <alias <alias> <certificate | summary>| all>

For usage examples, refer to apps keystore.

show apps listener alias <alias>

For usage examples, refer to apps listener.

show apps metadata

app-profile [alias <alias> | all]

cache [alias <alias> | all]

exporter [alias <alias> | all]

monitoring [all | port-list <alias>]

stats [cache [alias <alias> | all]

exporter [alias <alias> | all]

mgmt interface [all | exporter alias <alias>]

monitoring [all | port-list <alias>]

 


show apps netflow [exporter | monitor | port-id | record] [alias <alias> | all | stats [alias <alias> | all]]

 

show apps port-throttle <alias <alias> | all>

For usage examples, refer to apps netflow.

show apps regrex-profile <alias <alias> | all>

For usage examples, refer to apps regrex-profile.

show apps sip-whitelist <alias <alias> | all>

For usage examples, refer to apps sip-whitelist.

show apps split-dns profile <alias <alias> | all>

For usage examples, refer to apps split-dns

show apps ssl
   key <alias <alias> | all>
   service <alias <alias> | all> stats [alias <alias> | all]

For usage examples, refer to apps ssl.

show crypto acme client info

Displays the acme client information and the status of the certificate.

For usage examples, refer to crypto.

show banner

For usage examples, refer to banner.

show battery

For usage examples, refer to battery.

show battery optimization

For usage examples, refer to battery optimization.

show bonds [bonded interface]

For usage examples, refer to bond.

show buffer
   box-id <box ID>
  port <port-list> [rx | tx]
   slot <slot ID>

For usage examples, refer to card (GigaVUE H Series) and port.

show buffer-index

For usage examples, refer to port.

show cards [box-id <box ID> | slot <slot ID>]

For usage examples, refer to card (GigaVUE H Series).

show chassis [box-id <box ID>]   [faceplate-numbering]

Displays ONIE faceplate numbering to GigaVUE‑OS faceplate numbering. This command only applies on a white box. For more information, refer to White Box Port and Faceplate Labeling.

show cli [history [number of lines]]

For usage examples, refer to cli.

show clock

For usage examples, refer to clock.

show cluster
   box-id <box ID>
   configured
   global [brief]
   history [box-id <box ID>]
   local [error-status]
   leader
   node <node ID>
   standby

For usage examples, refer to cluster.

show condition [alias <alias> | detail]

For usage examples, refer to policy.

show configuration
   audit
   files [filename | initial]
   full
   running [full]
   text files

For usage examples, refer to configuration.

show crypto certificate
   ca-list [default-ca-list]
   default-cert [detail | public-pem]
   detail
   name <cert-name> [system-self-signed] [detail | public-pem]
   public-pem

For usage examples, refer to crypto.

show diag

show diag [detail]

 

 

show diag detail upload <upload URL>

Displays diagnostics for trouble-shooting.

Displays diagnostic information about fabric statistics, system-health, and inline-ssl statistics detail, in addition to the diagnostic information displayed in show diag.

Uploads the output of show diag detail to the specified URL.

show egress-vlantag

For usage examples, refer to port.

show email [dead-letter | events]

For usage examples, refer to email.

show environment
   box-id <box ID> slot <slot ID> type <fan | temperature | voltage | psu>

Displays environment information.

show environment type psu psu-detail [all | psu-id]

Displays the PSU diagnostic attributes parameters for all the PSU modules or for the specified PSU module id (psu-id). Depending on the number of PSU modules in the chassis, psu-id can be 1, 2, etc.

The nomenclature for the power module parameter is as follows:

N/A - Not Applicable
OK - Fault has not set
Check - Fault has set
Read Err - Could not read

Rules and Notes

Keep in mind the following exceptions and limitations:

If a GigaVUE node is unable to read the product code of the Power Supply Unit (PSU) module, then all the PSU parameters will be displayed as N/A except the following parameters:
o Product Code
o Serial Number
o Hardware Revision
o Status
In addition to the above parameters, for GigaVUE-HC3, the value for the "capacity" parameter will also be displayed as N/A.
Minimal output voltage (such as 0.63 V) and minimal output current (such as 0.2 A) is expected when the PSU module is in the "off" state. This behavior is due to a voltage leak. In GigaVUE-HC3 node, the input under "voltage fault" is set only when there is a real under-voltage condition.
In some modules, the temperature fault is latched, which means that if an over-temperature condition occurs, the temperature fault is set. When the PSU temperature drops and remains within a safe range, the PSU module will shut down and will restore power automatically, but the temperature fault will remain set. The only time the fault setting is cleared is when the PSU is power-cycled. This behavior occurs in the following modules:
o GigaVUE-TA200
o GigaVUE-HC1

show files <debug-dump | pcap | system [detail] | tcpdump>

For usage examples, refer to file and pcap.

show filter-resource [all] | [box-id <box ID>] | [slot-id <slot ID>] [brief]

For usage examples, refer to filter-template.

show filter-template [alias <alias> [brief] | all | limit [all | box <box ID> | slot <slot ID>]

For usage examples, refer to filter-template.

slot ID > [brief]]

For usage examples, refer to chassis.

engine <port-list> <arp | details | stats> | interface [eth2 | eth3] <vlan <VLAN ID>> <arp | details | stats>

For usage examples, refer to gigasmart.

show gigastream
   advanced-hash [box-id <box ID> | brief | slot <slot ID>
   alias <alias>
   all
   brief

For usage examples, refer to gigastream.

show gsgroup
   alias <alias>
   all
   flow-ops-report alias <alias> type
      flow-sampling | ssl-decryption <any | device-ip-mask <IP address> <netmask> | flow-filtering <gtp-imsi-pattern | imei-pattern | msisdn-pattern > [summary | upload <upload URL>] flow-sip <any | callerid-pattern> [summary | upload <upload URL>]      inline-ssl any upload <upload URL>

flow-5g <supi-pattern | pei-pattern | dnn-pattern > [summary | upload <upload URL>    flow-whitelist alias <GTP whitelist file alias> imsi       <IMSI number>   gsapp-resource <alias <alias> | all>   gtp-persistence <alias <alias> | all>   sip-whitelist <alias <alias> caller-id <caller ID>>   stats [alias <alias> | all]

For usage examples, refer to gsgroup.

Refer to “Viewing GigaSMART Statistics” section in the GigaVUE Fabric Management Guide for more information.

show gsop
   alias <alias>
   all
   by-application <add-header | dedup | apf | asf | flow-sampling | flow-filtering | lb | masking | slicing | strip-header | trailer | tunnel-decap | ssl-decrypt>   stats [alias <alias> [ip-frag] | all [detail] | by-application <add-header | dedup | apf | asf | flow-sampling | flow-filtering | lb | masking | slicing | strip-header | trailer | tunnel-decap | ssl-decrypt]  by-gsgroup <GS group alias>>

For usage examples, refer to gsop.

Refer to the “Viewing GigaSMART Statistics” section in the GigaVUE Fabric Management Guide for more information.

show gsparams [alias <alias> | all]

For usage examples, refer to gsparams.

Refer to the “Viewing GigaSMART Statistics” section in the GigaVUE Fabric Management Guide for more information.

show gmon speed-port-group

Displays all speed port groups of GigaVUE‑TA25E.

show hb-profile
   [alias <alias> | default]   [all]

For usage examples, refer to hb-profile.

show hosts

For usage examples, refer to hostname.

show ib-pathway traffic-rate {all | alias <ib_name>}

Displays the Rx and Tx statistics for either all the inter-broker pathway or a specified inter-broker pathway alias that are part of the inline flow deployment. Refer to ib-pathway.

show images

For usage examples, refer to image.

show ingress-vlan-tag

For usage examples, refer to port.

show inline-netlag traffic-rate [all | alias <alias_name>]

Displays the Rx and Tx statistics for either all the inline netlags or a specified inline netlag alias that are part of the inline flow deployment.

show inline-network   [alias <alias> | all | brief]

For usage examples, refer to inline-network.

show inline-network-group   [alias <alias> | all]

For usage examples, refer to inline-network-group.

show inline-serial   [alias <alias> | all]

For usage examples, refer to inline-serial.

show inline-tool   [alias <alias> | all] [brief] [vlan-mapping]

For usage examples, refer to inline-tool.

show inline-tool-group   [alias <alias> | all]

For usage examples, refer to inline-tool-group.

show interfaces <interface name>   [brief | configured]

For usage examples, refer to interface.

show ip
   default-gateway [static]
   dhcp
   filter [all | configured]
   route [static]

For usage examples, refer to ip.

show ip interface [alias | all | stats]

For usage examples, refer to ip interface.

show apps icap server all | <alias>

For usage examples, refer to apps icap.

show arp

Displays all ARP information, including both static and dynamic entries.

show ipv6 neighbors

Displays all IPv6 neighbor information, which is part of the IP interface configuration. (The configuration is done as part of the IP interface in GVOS with IPv6).

show ipv6
   default-gateway [static]
   dhcp
   filter [all | configured]
   neighbors [static]
   route [static]

For usage examples, refer to ipv6.

show jobs   [job ID]

For usage examples, refer to job.

show ldap

For usage examples, refer to ldap.

show license [box-id <box ID>]

For usage examples, refer to license.

show load-balance port-group stats <alias> <port-group name> | all>

For usage examples, refer to port-group.

show log
   continuous [matching <reg exp> | not matching <reg exp>]
   files <file number> [matching <reg exp> | not matching <reg exp>]
   matching <reg exp>
   not matching <reg exp>

For usage examples, refer to logging.

show logging

For usage examples, refer to logging.

show logging port

Displays the minimum severity of certain port log messages.

show map
   access
   alias <alias>
   all
   assignment [alias <alias> | all]
   brief
   mode
   priority alias <alias>]
   stats <alias <alias> [rule <rule ID>] | all>

For usage examples, refer to map.

alias <alias> | all]

For usage examples, refer to map.

alias <alias> | all | brief]

For usage examples, refer to map-group.

alias <alias> | all | brief]

For usage examples, refer to map-passall.

alias <alias> | all | brief]

For usage examples, refer to map-scollector.

show memory

For usage examples, refer to write.

show nhb-profile   [alias <alias> | all]

For usage examples, refer to nhb-profile.

show notifications

For usage examples, refer to notifications.

show ntp [configured]

For usage examples, refer to ntp.

show pld [slot <slotID>]

For usage examples, refer to pld.

show policy [alias <alias> | detail]

For usage examples, refer to policy.

show port   access [all | box-id <box ID> [brief] | port-list       <port list> [brief] | slot <slot ID> [brief]]   alias   assignment [all | box-id <box ID> [brief] |      port-list <port list> [brief] | slot <slot ID>       [brief]]   comment   discovery [all | box-id <box ID> [brief] | brief       [port-list <port-list>] | port-list <port list>       [brief] | slot <slot ID> [brief]]   faceplate-number-mapping port-list <port list>   filter [port-list <port list>]   in-use [type <network | tool | hybrid |      inline-network | inline-tool | gs>]   mode [box-id <box ID> | slot <slot ID>]   params       all       box-id <box ID> [in-use] | [brief] | [type] | [unused]      brief [port-list <port list>]      in-use [type <network | tool | hybrid |          inline-network | inline-tool | gs>]      port-list <port list> [brief]      slot <slot ID> [brief] | [in-use] | [type] | [unused]      type <network | stack | tool | hybrid |          inline-network | inline-tool | gs>      unused [type <network | stack | tool | hybrid |          inline-network | inline-tool | gs>]   port-number-mapping port-list <port list>   stats [all | box-id <box ID> | port-list <port list> |       slot <slot ID>]  threshold [drop | error] [all | box-id <box ID> | port-list <port list>]  tool-share [all | box-id <box ID> | port-list       <port list> | slot <slot ID>]   type <network | stack | tool | hybrid | inline-network |       inline-tool | gs>   unused [type <network | stack | tool | hybrid |      inline-network | inline-tool | gs>]   utilization [all | box-id <box ID> | port-list       <port list> | slot <slot ID>]

For usage examples, refer to port.

show port-group [alias <alias> | all | brief]

For usage examples, refer to port-group.

show port-pair [alias <alias> | all | brief]

For usage examples, refer to port-pair.

show profile <current | history>   buffer [port-list <min | hour | day | week | cur>] |       <all>   port [port-list <min | hour | day | week | cur>] |       <all>   utilization [port-list <min | hour | day | week |       cur>] | <all>

For usage examples, refer to card (GigaVUE H Series) and port.

show pseudo-slot portmap [box-id <box ID>]

For usage examples, refer to filter-template.

show ptp [box-id <box ID> | configured]

For usage examples, refer to ptp.

show radius

For usage examples, refer to radius-server.

[alias <alias> | all]

For usage examples, refer to redundancy-profile.

show roles [assignment] [alias <alias> | all]

Displays the currently configured roles.

show running-config [full]

Displays commands to recreate current running configuration.

show serial

For usage examples, refer to serial.

show snmp [engineID | events | host]

For usage examples, refer to snmp-server.

[alias <alias> | all | brief]

For usage examples, refer to spine-link.

show ssh <client | server [host-keys]>

For usage examples, refer to ssh.

show stack-link [alias <alias> | all | brief]

For usage examples, refer to stack-link.

show system stacking-mode

For usage examples, refer to system.

show sync

For usage examples, refer to sync.

show system

For usage examples, refer to system.

show system-health [box-id <box ID> | config [box-id <box ID>] | status [box-id <box ID>]]

For usage examples, refer to system-health.

show tacacs

For usage examples, refer to tacacs-server.

show terminal

For usage examples, refer to terminal.

show timestamp [box-id <box ID>]

For usage examples, refer to timestamp.

show tool-mirror [alias <alias> | all | brief]

For usage examples, refer to tool-mirror.

show traffic [all | brief | port <port-list> | slot <slot ID> | vport alias <alias> | all]

Displays traffic forwarding schemes.

show sffp-profile [alias <alias> | all]

For usage examples, refer to sffp profile.

show tunnel

Reserved for future use.

show tunnel-endpoint [alias | state <port-list    <GS port ID | GS group alias>> | stats <port-list    <GS port ID | GS group alias>> | te-id <te ID>]

For usage examples, refer to tunnel-endpoint.

show usernames [assignment] [alias <alias> | all]

For usage examples, refer to username.

show users [history [username <username>] |    roles]

For usage examples, refer to username.

show version [all | box-id <box ID> | chassis-serial    <chassis serial number> | concise]

Displays version information for current system image.

show vlan-resource

Displays the VLAN resource that are available.

show vport [alias <alias> | all | mmon-report <alias>| sensor-diag <alias> | stats [alias <alias> |    all]]

 

For usage examples, refer to vport.

show vport mmon-report is supported only on Generation 2 GigaSMART Module.

show web

For usage examples, refer to web.

show whoami

Displays the identity and roles of the current user.