reset
Required Command-Line Mode = Configure
Required User Level = Admin
Use the reset command to return the GigaVUE H Series node to factory settings.
The reset command has the following syntax:
reset factory <all | keep-all-config | only-traffic>
The system is rebooted after the process completes.
Note: Starting in software release 5.2 on the GigaVUE-HB1 node, issue the card all or card slot 1 command to bring up the chassis, especially after configuring it for the first time, or after issuing the reset factory all command.
Note: To halt the system, use reload halt. Refer to reload (reboot).
The following table describes the arguments for the reset command:
Command |
Description |
|||||||||
factory <all | keep-all-config | only-traffic> |
Specifies the portions of the system configuration to reset to factory defaults:
Note: The reset factory only-traffic command reloads the node without issuing the reload command. Examples: (config) # reset factory all (config) # reset factory keep-all-config (config) # reset factory only-traffic Note: Using reset factory deletes passwords on user accounts. When you login with the admin account, you will be prompted for a new password through the jump-start script. |