Configure Application Metadata Intelligence for Virtual Environment
Application Metadata Intelligence (AMI) can be configured in the Monitoring Session Canvas. To add Application Metadata Intelligence application to the canvas, follow the steps given below:
- Drag and drop Application Metadata from APPLICATIONS to the graphical workspace.
- Click the Application Metadata application and select Details. The Application quick view appears.
- In the Application quick view, enter or select the following details in the General tab:
Parameter
Description
Name
Enter a name for the application.
Description
Enter the description.
Application Metadata Settings
Flow Direction
Enable or Disable Bi-Directional Flow behavior. Bi-Directional is enabled by default. Disable this option for Uni-Directional Flow behavior.
Timeout
Specify the traffic flow inactivity timeout, in seconds. The session will be removed due to inactivity when no packets match.
Multi Collect
Enable: Enables the multi-collect of attributes within a given Metadata Store cache which means that if a configured attributes is seen in multiple packets within the same flow, each of these information is collected. Multi Collect is enabled by default, when a new cache is created. Multi Collect is enabled, when upgraded from an older release. Disable: Disables the multi-collect of attributes within a given Metadata Store cache. Note: Do not enable this option if you are going to export the Application Metadata using the AMX application. There can be only one attribute in a JSON object, therefore Multi-collect is not supported when configuring the AMX application.
Data Link
If you want to include the VLAN ID along with the 5-tuple to identify the traffic flow, select the Data Link and enable the VLAN option.
Observation ID
Enter a value to identify the source from where the metadata is collected. The range is from 0 to 255. The calculated value of Observation Domain Id in Hexadecimal is 00 01 02 05, and in Decimal is 66053.
Advanced Settings
Number of Flows
The number of flows supported by the application.
Refer to the following table for the maximum number of flows supported for VMware, AWS, and Azure platforms.Cloud Platform Instance Size
Maximum Number of Flows
VMware
Large (8 vCPU and 16 GB RAM)
200k
AWS
Large (c5n.2xlarge)
300k
Medium (t3a.xlarge)
100k
Azure
Large (Standard_D8s_V4)
500k
Medium (Standard_D4s_v4)
100k
Nutanix
Large (8 vCPU and 16 GB RAM)
200k
Note: Medium Form Factor is supported for VMware ESXi only when secure tunnels option is disabled. The maximum Number of Flows for VMware ESXi when using a medium Form Factor is 50k.
Fast Mode
Enable the Fast Mode option for performance (less CPU cycles and less memory utilization) improvement. When the Fast Mode is enabled, some or all of the attributes of the applications will be disabled. If all the attributes of the application are disabled then the application itself is disabled. Refer to Fast Modesection for more information on the benefits and Limitations of the Fast Mode.
Aggregate Round-trip Time
Enable this option to export the minimum, maximum, and mean of RTT values for the following list of supported protocols and attributes and also the aggregate of TCP Lost byte values collected per export time interval.
Protocol Arrtibute http
rtt
icmp
rtt
icmp6
rtt
ssh
rtt
tcp
rtt
tcp
rtt_app
telnet
rtt
wsp
connect_rtt
wsp
query_rtt
- In the Application quick view, enter or select the following details in the Exporters tab:
Parameter
Description
Exporter Name
Enter a name for the Exporter.
Actions
Using this option, you can perform the following functions:
Add Exporter - Use to add a new Exporter to this Application Metadata Intelligence Application. A maximum of 5 exporters can be added. Apply Template - Use to select the tool template. Refer to Tool Templates for more information on tool templates and how to create custom tool templates. Save as New Template - Use to save the current configuration as a new custom tool template. Delete this Exporter - Use to delete the Exporter. APPLICATION ID
Enable to export the data with Application Id.
Format
Select NetFlow or CEF
NetFlow: Select this option to use NetFlow
Record / Template type
Segregated - The application-specific attributes and the generic attributes will be exported as individual records to the tool. Cohesive- The application-specific attributes and the generic attributes will be combined as a single record and exported to the tool. Active Timeout
Enter the active flow timeout value in seconds.
Inactive Timeout
Enter the inactive flow timeout in seconds.
Version
Select the NetFlow version. The supported versions are V5, V9, IPFIX(V10).
Template Refresh Interval
Enter the time interval at which the template must be refreshed in seconds
CEF: Select this option to use CEF
Record / Template type
Segregated - The application-specific attributes and the generic attributes will be exported as individual records to the tool. Cohesive- The application-specific attributes and the generic attributes will be combined as a single record and exported to the tool. Active Timeout
Enter the active flow timeout value in seconds.
Inactive Timeout
Enter the inactive flow timeout in seconds.
APPLICATION & ATTRIBUTES:
Select the applications and their attributes for traffic filtering by layer seven applications. You can select a maximum of 64 attributes for each of the application. (Not applicable when using NetFlow V5 Template in the above Template drop-down menu.)
Click on the Add Application button. The Add Application dialog box opens.
Select an Application Family and the Applications that needs to be filtered from the traffic.
NETWORK & TRANSPORT PARAMETERS:
Select the Network and the transport packet attributes with the respective parameters
Data Link
Select any one of the parameters such as Source MAC address, Destination MAC Address and VLAN.
Interface
Select any one of the parameter such as Input Physical, Output Physical and Input Name.
IP
Select the parameter as Version if required.
IPv4
Select the required attributes. By default, Source Address, Destination Address, and Protocol are enabled.
IPv6
Select the required attributes. By default, Source Address, Destination Address, and Next Header are enabled.
Transport
Select the required attributes. By default, Source Port, Destination Port are enabled.
Counter
Select the Bytes, and Packets.
Timestamp
Select the required timestamp such as System Uptime First, Flow Start, System Uptime Last, and Flow End.
Flow
Select the parameter as End Reason if required.
GTP-U
Select the required parameters such as QFI and TEID.
Outer IPv4
Select any one of the parameter such as Source or Destination.
Outer IPv6
Select any one of the parameter such as Source or Destination.
- Click Save to deploy the Application Metadata application.
After adding the Application Metadata application and deploying Monitoring Session, you cannot change the Aggregate Round Trip time option.
When using Application Metadata, if you create a tunnel to tunnel the output to the tools, then select the tunnel type as UDP.
When using Application Metadata application, you can either use a single tunnel to export all the metadata from the application or use a separate tunnel for each exporter configured.