Monitoring Session Options
You can enable the Options page for the monitoring session from Prefiltering, Precyption, Secure tunnel, User-defined applications, and Thresholds.
To navigate to Options page, follow these steps:
- Go to Traffic > Virtual > Orchestrated Flows > Select your cloud platform.
- Select a monitoring session from the list view, select Actions > Edit. The Edit Monitoring Session page appears.
- In the Edit Monitoring Session page, select Options. The Options page appears.
You can perform the following actions in the Options page:
Enable Prefiltering
To enable Prefiltering, follow these steps:
- In the Monitoring Session Options page, select the Mirroring tab.
- Enable the Mirroring toggle button.
- Enable the Secure Tunnel button if you wish to use Secure Tunnels. For more information, refer to Secure Tunnels.
- Select an existing Prefiltering template from the Template drop-down menu or create a new template and apply it. For details on how to create a template, refer to Prefiltering.
- Select Save to apply the template to the monitoring session.
You can use the Save as Template button to save the newly created template.
Enable Precryption
To enable Precryption, follow these steps:
- In the Monitoring Session Options page, select Precryption tab.
- Enable the Precryption toggle button. For details, refer to Precryption™.
- (Optional) Enable the Secure Tunnel button if you wish to use Secure Tunnels. For more information about Secure Tunnel, refer to Secure Tunnels.
Enable User Defined Applications
To enable user defined application, follow these steps:
- In the Monitoring Session Options page, select the User-Defined Apps tab.
- Enable the User-defined Applications toggle button. For details, refer to User Defined Application.
Create Threshold
To create threshold, follow these steps:
- Go to the Monitoring Session Options page.
- Select the Threshold tab.For details, refer to Traffic Health Monitoring.