Configuration Netflow Generation Example
Configure NetFlow Generation
The following are the step for setting up a typical NetFlow Generation configuration with GigaVUE-FM:
Step 1: Configure a GigaSMART Group |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |
Configuration Netflow Generation Example |

Configure a GigaSMART Group using the following steps. you will use this GigaSMART Group in Configuration Netflow Generation Example, where you assign a NetFlow Monitor to the group.
1. | From the device view, select GigaSMART > GigaSMART Groups. |
2. | Click New to create a new GigaSMART Group or select an existing GigaSMART Group and click Edit. |
3. | Enter an alias to help identify this GigaSMART group. For example, Netflow-gsgrp |
4. | Select an engine port (the e port references the GigaSMART line card or module) Your GigaSMART group should look similar to the example shown in the following figure. |
5. | Click Save. |
Notes:
The GigaSMART Group can contain multiple GigaSMART engine ports. |
Only one NetFlow Generation Monitor can be configured per GigaSMART Group. |