Loss Summary Specifications

Refer to Table 1: Loss Summary for Bypass Combo Module for loss summary for Bypass Combo Module.

Table 1: Loss Summary for Bypass Combo Module

Type

@

 

Operating

Wavelength

(nm)

Cable Type

Max Fiber Length

Max Receiver Sensitivity (dBm)

Insertion Loss

(dB)

Launch Power(dBm)

 

Symbol

Min

Typical

Max

MPO to MPO

 

BPS-HC3-C25F2G

100Gb

NA

840

850

860

MPO

30m

-10.3

1.0

-8.4 to 2.4

40Gb

NA

840

850

860

MPO

30m

-9.5

1.0

-7.6 to 2.4
BPS-HC3-C35C2G

100Gb

 

L0 1294.53 1295.56 1296.59 LC 10km -8.6 1.2 -4.3 to 4.5
L1 1299.02 1300.05 1301.09
L2 1303.54 1304.58 1305.63
L3 1308.09 1309.14 1310.19
BPS-HC3-Q35C2G 40Gb L0 1264.5 1271 1277.5 LC 10Km -11.5 1.2 -7.0 to 2.3
L1 1284.5 1291 1297.5
L2 1304.5 1311 1317.5
L3 1324.5 1331 1337.5