How to Use Both Ingress Tagging and Egress Stripping
When ingress port VLAN tagging is enabled on a network port and egress port VLAN stripping is enabled on a tool port on the same GigaVUE node, refer to the Table 1: VLAN Stripping Table:
Tool à |
Stripping Enabled | Stripping Disabled | ||||
Network |
Untagged |
Single Tag |
Double Tag |
Untagged |
Single Tag |
Double Tag |
Ingress VLAN tag enabled |
None |
None |
Customer VLAN tag |
Ingress VLAN tag |
Ingress VLAN tag + Customer VLAN tag |
Ingress VLAN tag + Customer VLAN tag + Service VLAN tag |
Ingress VLAN tag disabled |
None |
None |
Customer VLAN tag |
None |
Customer VLAN tag |
Service VLAN tag |
NOTES:
The inner VLAN tag is classified as the Customer VLAN tag (ethertype 0x8100) |