Displaying Ports
Use the show port command to display all ports in a table format. The output of the command is as follows:
(config) # show port
Use the show port params command to display port parameters. The output of the command on GigaVUE H Series nodes is as follows:
(config) # show port params port-list 11/3/x1
Parameter 11/3/x1
====================== ===============
Name Alias: -
Type: network
Admin: enabled
Link status: up
Auto Negotiate: off
Duplex: full
Speed (Mbps): 10000
MTU: 9400
Force Link Up: off
Port Relay: N/A
Port Role: N/A
Ingress Vlan Tag: -
Egress Vlan Tag: none
Buffer Index: high
Discovery: off
GDP: enable
Timestamp: -
Source-id: -
SFP type: sfp+ sr
SFP vendor name: GIGAMON SFP-532
SFP vendor PN: GMON8571D3BCL-G
SFP vendor SN: AQP1LNY
SFP Power (1-2) (dBm): -2.77
SFP Power (3-4) (dBm): - -
SFP Power (5-6) (dBm): - -
SFP Power (7-8) (dBm): - -
SFP Power (9-10)(dBm): - -
SFP Temperature (C): N/A
Alarm THld (H-L)(dBm): 0.00 -20.00
Alert THld (H-L)(dBm): -1.00 -18.01
Power THld Status: Normal
Comment:
Note: The output of the show port params command on GigaVUE TA Series nodes and the Certified Traffic Aggregation White Box do not have values for the power thresholds as follows:
(config) # show port params slot 8
...
Alarm THld (H-L)(dBm): N/A
Alert THld (H-L)(dBm): N/A
Power THld Status: N/A
Comment:
Note: The output of the show port params command on GigaVUE‑HC2, GigaVUE HD Series, GigaVUE-TA100, GigaVUE-TA100-CXP, GigaVUE‑HC3, or GigaVUE-TA200 and GigaVUE‑TA25 nodes equipped with 100Gb ports and QSFP28 transceivers, display an SFP temperature as follows:
(config) # show port params port-list 13/4/c1..c2
...
SFP type: qsfp28 sr qsfp28 sr
SFP vendor name: GIGAMON GIGAMON
SFP vendor PN: FTLC9551REPM FTLC9551REPM
SFP vendor SN: XU60DZN XU60DZS
SFP Power (1-2) (dBm): -40.00 -40.00 -40.00 -40.00
SFP Power (3-4) (dBm): -40.00 -40.00 -40.00 -40.00
SFP Power (5-6) (dBm): - - - -
SFP Power (7-8) (dBm): - - - -
SFP Power (9-10)(dBm): - - - -
SFP Temperature (C): 20.94 21.12
...
Note: The output of the show port params command on GigaVUE-TA100-CXP nodes equipped with 100Gb ports and CXP transceivers, display an SFP temperature as follows:
(config) # show port params port-list 1/1/c1
...
SFP type: cxp sr
SFP vendor name: GIGAMON
SFP vendor PN: FTLD10CE3C-GM
SFP vendor SN: XWG0J50
SFP Power (1-2) (dBm): -40.00 -40.00
SFP Power (3-4) (dBm): -40.00 -40.00
SFP Power (5-6) (dBm): -40.00 -40.00
SFP Power (7-8) (dBm): -40.00 -40.00
SFP Power (9-10)(dBm): -40.00 -40.00
SFP Temperature (C): 23.88