Example 3: Protected Inline Bypass Using Combo Modules

Example 3 is a protected inline bypass solution using bypass combo modules on GigaVUE‑HC2. It also configures heartbeat and negative heartbeat profiles.

Protected inline networks are based on the pairs of ports associated with the physical protection switches located on the bypass combo modules. Unlike the unprotected examples, you do not need to configure inline network ports because they are created automatically. On GigaVUE‑HC2, the port pairs are numbered for example: 2/2/x17 and 2/2/x18, 2/2/x19and 2/2/x20, 2/2/x21 and 2/2/x22, 2/2/x23 and 2/2/x24.

You do not need to configure inline networks because they are also created automatically on bypass combo modules. The aliases of the default inline networks are: default_inline_net_2_2_1, default_inline_net_2_2_2, default_inline_net_2_2_3, default_inline_net_2_2_4.

On GigaVUE‑HC3, protected inline bypass can be configured on the bypass combo module on ports c1..c4.

On GigaVUE‑HC1, protected inline bypass can be configured on the bypass combo module. It can also be configured on the TAP-HC1-G10040 module placed in either bay 2 or bay 3, so the ports will be 1/2/g1..g8 or 1/3/g1..g8.

Note:  The default value of the physical-bypass attribute of protected inline networks is set to enable, which means that the fibers attached to ports net-a and net-b of the inline network are optically coupled and the traffic is exchanged between end nodes without coming to the switching fabric. of the GigaVUE node. As shown in Example 4, after configuring the inline tool and the map passall, the physical-bypass attribute is set to disable in order to activate the inline-bypass solution.

 

Task

Description

UI Steps

1.    

Configure inline too aliases, port type (inline-tool), and administratively enable inline network ports.

1. From the left navigation pane, go to System > Ports > Ports > All Ports.
1. Click Quick Port Editor.
2. Use Quick search to find the ports to configure. In this example, the ports are 2/2/x11 and 2/2/x12
3. Set port 2/2/x11 to Type Inline Tool and select Enable. Enter iT1 for the port alias.
4. Set port 2/2/x12 to Type Inline Tool and select Enable. Enter iT2 for the port alias.
5. Click OK.
2.  

Configure a heartbeat profile.

1. Select Inline Bypass > Heartbeats.
6. Click New.
7. In the Alias field, type hb2.
8. For Type, select Regular.
9. Click Save.
3.  

Configure negative heartbeat profile alias and PCAP file

1. Select Inline Bypass > Heartbeats.
10. Click New.
11. In the Alias field, type nhb1.
12. For Type, select Negative.
13. Click the Browse button for Custom Format and upload the pcap file; for example, hnb.pcap.
14. Click Save.
4.  

Configure inline tools, and enable them. Also specify the heartbeat profile.

1. Select Inline Bypass > Inline Tools.
15. Click New.
16. In the Alias field, type InTool1.
17. For Port A, select iT1.
18. For Port B, select iT2.
19. Under Configuration:

a. Select Enabled

b. Select Enabled Regular Heartbeat and set Profile to hb2.

c. Select Enabled Negative Heartbeat and set Negative Heartbeat Profile to nhb1.

20. Click Save.

Configure the second inline tool.

1. Select Inline Bypass > Inline Tools.
21. Click New.
22. In the Alias field, type InTool2.
23. For Port A, select iT3.
24. For Port B, select iT4.
25. Under Configuration:

a. Select Enabled

b. Select Enabled Heartbeat and set Profile to hb_custom.

26. Click Save.
5.  

Configure the inline tool group and enable it.

1. Select Inline Bypass > Inline Tool Group
27. Click New.
28. In the Alias field, type inToolGroup.
29. For Inline Tools, select InTool1 and InTool2.
30. Under Configuration, select Enabled.
31. Click Save.
6.  

Configure map passall, from inline network to inline tool.

1. Select Maps > Maps.
32. Click New.
33. In the Alias field, type InMap.
34. Select Inline for Type and Pass All for Subtype.
35. For Source, select default_inline_net_2_2_1
36. For Destination, select InTool1
37. Click Save.
7.  

Configure the path of the traffic to inline tool and disable the physical bypass

1. Select Inline ByPass > Inline Networks.
38. Select the Inline Network default_inline_net_2_2_1 and click Edit
39. Under Configuration, set the Traffic Path field to To Inline Tool.
40. Make sure Physical Bypass is not selected.
41. Click Save.