Module and Port Numbering
Network and tool ports are numbered using standard conventions. The numbering is displayed in the module faceplates and also in the Chassis view when hovering over a port. On faceplates, the ports are numbered are as follows:
400Gb Ports |
Numbered with a leading D. For example, the GigaVUE-TA400 built-in module includes 32 400Gb/100Gb/ 40Gb QSFP-DD/ QSFP28/QSFP+ ports. |
100Gb Ports |
Numbered with a leading C. For example, the SMT-HC3-C05 includes five 100Gb ports C1 to C5. |
40Gb Ports |
Numbered with a leading Q. For example, the PRT-HC0-Q06 includes 40Gb ports Q1 to Q6. |
25Gb/10Gb/1Gb Ports |
Numbered with a leading X. For example, the PRT-HC3-X24 includes twenty-four 25Gb ports X1 to X24. |
10/100/1000 Ports |
Numbered with a leading G. For example, the PRT-HC1-X12G4 includes 10/100/1000 ports G1 to G4. |
The port labels on the module faceplates use upper-case C, Q, X, and G characters to identify ports. However, Chassis View ) uses lowercase notation to refer to ports (for example, c1, q1, x4, and g1).
When displaying ports in Chassis View , the format is box ID/slot ID/port ID. For example, 1/1/x6 refers to box 1, slot 1, port X6.
On chassis with multiple slots/bays, the slots or bays are numbered as follows:
GigaVUE‑HC1and GigaVUE-HC1-Plus: Bays are numbered as follows: |
the base chassis in the center, is numbered 1 |
the left module is numbered 2 |
the right module is numbered 3 |
GigaVUE‑HC2: Bays are numbered 1-4 from left upper, left lower, right upper to right lower. |
GigaVUE‑HC3: Bays are numbered 1-4 from left upper, left lower, right upper to right lower. |