Transceiver—Rules and Notes
Keep in mind the following rules and notes when you connect and use GigaVUE TA Series nodes with transceivers:
|
•
|
Always use transceivers purchased from Gigamon to ensure interoperability and performance. Gigamon does not support transceivers purchased from other vendors. |
|
•
|
After removing an optical transceiver, the best practice is to wait ten (10) or more seconds before re-inserting the same or different optical transceiver. |
|
•
|
Use the show port params all command to see transceiver type information for each of the network/tool ports in the GigaVUE TA Series nodes. Check the value of the SFP type field for the ports in question. |
|
•
|
Following are the nomenclatures for the GigaVUE TA Series node port numbers: |
|
•
|
Port numbers starting with a c (for example, c1) are 100Gb. |
|
•
|
Port numbers starting with a q (for example, q1) are 40Gb. |
|
•
|
Port numbers starting with an x (for example, x10) are 10Gb or 1Gb depending on the transceiver installed. |
Note: The 40Gb QSFP+ SR BiDi Full Duplex (RX/TX) transceiver is not supported in conjunction with a BiDi TAP.
|
•
|
For details about the supported transceivers, cable types, and connectivity specifications, refer to “GigaVUE-OS Compatibility and Interoperability Matrix”. |