Chassis Cooling

The fans on the GigaVUE-TA100 run at 100% of their maximum speed on power up, then drop to approximately 60% during normal operations. The temperatures of four components: transceivers, exhaust, CPU, and switch CPU, are monitored. When a component crosses a pre-defined threshold, the fan speed is adjusted dynamically, in increments of approximately 10%.

An SNMP trap is sent when a component reaches the threshold for warning, alert, or critical temperature conditions. Refer to Table 1: Component Temperature Thresholds and Actions for the temperatures at which the warning, alert, and critical traps are sent and any additional action that occurs at a threshold.

 

Table 1: Component Temperature Thresholds and Actions

Transceiver Temperature

Exhaust Temperature

CPU Temperature

Switch CPU Temperature

70ºC

Warning trap sent

85ºC

Warning trap sent

90ºC

Warning trap sent

105ºC

Warning trap sent

80ºC

Alert trap sent; Transceiver power disabled

90ºC

Alert trap sent

95ºC

Alert trap sent

115ºC

Alert trap sent;
Switch CPU put in reset

95ºC

Critical trap sent

95ºC

Critical trap sent

100ºC

Critical trap sent

140ºC

Critical trap sent

The output of the following CLI command displays the current exhaust, CPU, and switch CPU temperatures, as well as the intake temperature:

(config) show environment
...
 Card 1 (TA100-C32):
 Intake temperature :           40 C
 Exhaust temperature :          45 C
 CPU temperature :              32 C
 Switch_CPU temperature :       54 C

The output of the following CLI command displays the transceiver temperature:

(config) show port params port-list 1/1/c1..c2
              Parameter           1/1/c1           1/1/c2
 ======================  ===============  ===============
...
SFP type:        qsfp28 sr        qsfp28 sr
...
 SFP Power (1-2) (dBm):    -40.00 -40.00    -40.00 -40.00
 SFP Power (3-4) (dBm):    -40.00 -40.00    -40.00 -40.00
 SFP Power (5-6) (dBm):         -      -         -      -
 SFP Power (7-8) (dBm):         -      -         -      -
 SFP Power (9-10)(dBm):         -      -         -      -
 SFP Temperature (C):            20.94            21.12
...

The output of the following CLI command displays the fan speed in RPM (the normal operational speed is approximately 12000 RPM; the maximum speed is approximately 19000 RPM):

(config) show environment
...
 Fan tray 1 (FAN-TAC00):
 1st fan :                      12136 RPM
 2nd fan :                      12288 RPM
 3rd fan :                      12136 RPM
 4th fan :                      11988 RPM
...