Removing the Rear GigaSMART Module
Use the following procedure to remove the rear GigaSMART module from the node with the power on.
For removal of other GigaVUE-HC2 modules, refer to Module Removal and Replacement Procedure (Hot Removal).
Important: Hot removal of the GigaSMART module without following the listed steps can cause system instability and require a reboot.
Before starting, make sure you are wearing an ESD-preventive wrist or ankle strap.
1Save map rules with the following CLI command:
config text generate active running save <name.txt>
Refer also to Backing Up Running Configuration.
1. | Press the H/S button to prepare the module for removal. Wait for the LED to turn solid blue. |
2. | Slide the module out of chassis and store it in a static-safe location. |
3. | Insert the new GigaSMART module. |
4. | To verify the module is operationally up, issue the following CLI command: |
(config) # show cards
5. | Apply GigaSMART licenses with the following CLI command: |
license install box id <#> key