Configure GigaVUE Fabric Components in OpenStack

You can use your own OpenStack orchestration system to deploy GigaVUE fabric nodes and use GigaVUE-FM to configure the advanced features supported by these nodes. These nodes register themselves with GigaVUE-FM using the information provided by your OpenStack orchestration system. Once the nodes are registered with GigaVUE-FM, you can configure monitoring sessions and related services in GigaVUE-FM. Health status of the registered nodes are determined by the heartbeat messages sent from the respective nodes.

Note:  Deployment of GigaVUE fabric components through a third-party orchestrator is supported on Linux and Windows platforms. Refer to Linux G-vTAP Agent Installation and Windows G-vTAP Agent Installation for detailed information.

In your OpenStack dashboard, you can configure the following GigaVUE fabric components:

Configure V Series Nodes and Proxy in OpenStack

To configure V Series Nodes and V Series Proxy in OpenStack platform:

  1. Before configuring GigaVUE fabric components through OpenStack, you must create a monitoring domain in GigaVUE-FM. Refer to Create Monitoring Domain for detailed instructions.

    Note:  You can use OpenStack Orchestrator for GigaVUE fabric node configuration only using V Series 2 nodes.

  2. In the Monitoring Domain Configuration page, select No for the Use FM to Launch Fabric field as you are going to configure the fabric components in OpenStack Orchestrator.
  3. In your OpenStack environment, you can deploy V Series nodes or V Series proxy using the following methods:

Register V Series Nodes or V Series Proxy using OpenStack GUI

To register V Series nodes or proxy using the user data in OpenStack GUI:

  1. On the Instance page of OpenStack dashboard, click Launch instance. The Launch Instance wizard appears. For detailed information, refer to Launch and Manage Instances topic in OpenStack Documentation.
  2. On the Configuration tab, enter the Customization Script as text in the following format and deploy the instance. The V Series nodes or V Series proxy uses this customization script to generate config file (/etc/gigamon-cloud.conf) used to register with GigaVUE-FM.
    #cloud-config
    write_files:
     - path: /etc/gigamon-cloud.conf
     owner: root:root
     permissions: '0644'
     content:
         Registration:
    	groupName: <Monitoring Domain Name>
    	subGroupName: <Connection Name>
    	user: orchestration
    	password: orchestration123A!
    	remoteIP: <IP address of the GigaVUE-FM>
    	remotePort: 443
  • You can register your V Series node directly with GigaVUE‑FM or you can use V Series proxy to register your V Series node with GigaVUE‑FM. If you wish to register V Series node directly, enter the remotePort value as 443 or if you wish to deploy V Series node using V Series proxy then, enter the remotePort value as 8891.
  • Use only the default user and password details given in the user data.
  • If there is no monitoring domain in GigaVUE‑FM with the same monitoring domain name and connection name as given in your user data, then GigaVUE‑FM automatically creates a monitoring domain under AnyCloud and your V Series nodes or proxys gets deployed under that monitoring domain.
  • In this case, the Traffic Acquisition Tunnel MTU is set to the default value 1500. to edit the Traffic Acquisition Tunnel MTU, select the monitoring domain and click on the Edit Monitoring Domain option. Enter the Traffic Acquisition Tunnel MTU and click Save.

Register V Series Node or V Series Proxy using a configuration file

To register V Series node or proxy using a configuration file:

  1. Log in to the V Series node or proxy.
  2. Edit the local configuration file (/etc/gigamon-cloud.conf) and enter the following customization script.
    Registration:
    	groupName: <Monitoring Domain Name>
    	subGroupName: <Connection Name>
    	user: orchestration
    	password: orchestration123A!
    	remoteIP: <IP address of the GigaVUE-FM>
    	remotePort: 443

    Note:  If you wish to register V Series node using V Series proxy then, enter the remotePort value as 8891.

  3. Restart the V Series node or proxy service. 
    • V Series node:
      $ sudo service vseries-node restart
    • V Series proxy:
      $ sudo service vps stop

    The deployed V Series node or V Series proxy registers with the GigaVUE-FM. After successful registration the V Series node or proxy sends heartbeat messages to GigaVUE-FM every 30 seconds. If one heartbeat is missing ,the fabric node status appears as 'Unhealthy'. If more than five heartbeats fail to reach GigaVUE-FM, GigaVUE‑FM tries to reach the V Series node or proxy and if that fails as well then GigaVUE‑FM unregisters the V Series node or proxy and it will be removed from GigaVUE‑FM.

Configure G-vTAP Controller in OpenStack

To configure GigaVUE fabric components in OpenStack platform:

  1. Before configuring GigaVUE fabric components through OpenStack, you must create a monitoring domain in GigaVUE-FM. While creating the monitoring domain, select G-vTAP as the Traffic Acquisition Method. Refer to Create Monitoring Domain for detailed instructions.

    Note:  You can use OpenStack Orchestrator for GigaVUE fabric node configuration only using V Series 2 nodes.

  2. In the Monitoring Domain Configuration page, select No for the Use FM to Launch Fabric field as you are going to configure the fabric components in OpenStack Dashboard.
  3. In your OpenStack environment, launch the G-vTAP Controller using any of the following methods:

    Register G-vTAP Controller using OpenStack GUI

    To register G-vTAP Controller using the user data in OpenStack GUI:

    1. On the Instance page of OpenStack dashboard, click Launch instance. The Launch Instance wizard appears. For detailed information, refer to Launch and Manage Instances topic in OpenStack Documentation.
    2. On the Configuration tab, enter the Customization Script as text in the following format and deploy the instance. The G-vTAP Controller uses this customization script to generate config file (/etc/gigamon-cloud.conf) used to register with GigaVUE-FM.
      #cloud-config
      write_files:
       - path: /etc/gigamon-cloud.conf
       owner: root:root
       permissions: '0644'
       content:
           Registration:
      	groupName: <Monitoring Domain Name>
      	subGroupName: <Connection Name>
      	user: orchestration
      	password: orchestration123A!
      	remoteIP: <IP address of the GigaVUE-FM>
      	remotePort: 443
    • Use only the default user and password details given in the user data.
    • If there is no monitoring domain in GigaVUE‑FM with the same monitoring domain name and connection name as given in your user data, then GigaVUE‑FM automatically creates a monitoring domain under AnyCloud and your V Series nodes or proxys gets deployed under that monitoring domain.
    • In this case, the Traffic Acquisition Tunnel MTU is set to the default value 1500. to edit the Traffic Acquisition Tunnel MTU, select the monitoring domain and click on the Edit Monitoring Domain option. Enter the Traffic Acquisition Tunnel MTU and click Save.

    The G-vTAP Controller deployed in OpenStack appears on the Monitoring Domain page of GigaVUE-FM.

    Register G-vTAP Controller using a configuration file

    To register G-vTAP Controller using a configuration file:

    1. Log in to the G-vTAP Controller.
    2. Edit the local configuration file (/etc/gigamon-cloud.conf) and enter the following user data.
      Registration:
      	groupName: <Monitoring Domain Name>
      	subGroupName: <Connection Name>
      	user: orchestration
      	password: orchestration123A!
      	remoteIP: <IP address of the GigaVUE-FM>
      	remotePort: 443
    3. Restart the G-vTAP Controller service.
      $ sudo service gvtap-cntlr restart

    The deployed G-vTAP Controller registers with the GigaVUE-FM. After successful registration the G-vTAP Controller sends heartbeat messages to GigaVUE-FM every 30 seconds. If one heartbeat is missing ,the fabric node status appears as 'Unhealthy'. If more than five heartbeats fail to reach GigaVUE-FM, GigaVUE‑FM tries to reach the G-vTAP Controller and if that fails as well then GigaVUE‑FM unregisters the G-vTAP Controller and it will be removed from GigaVUE‑FM.

Note:  When you deploy V Series nodes or G-vTAP Controllers using 3rd party orchestration, you cannot delete the monitoring domain without unregistering the V Series nodes or G-vTAP Controllers.

Configure G-vTAP Agent in OpenStack

G-vTAP Agent should be registered via the registered G-vTAP Controller and communicates through PORT 8891.

Deployment of G-vTAP Agents through third-party orchestrator is supported on Linux and Windows platforms.

To register G-vTAP Agent using a configuration file:

  1. Install the G-vTAP Agent in the Linux or Windows platform. For detailed instructions, refer to Linux G-vTAP Agent Installation and Windows G-vTAP Agent Installation.

  2. Log in to the G-vTAP Agent.
  3. Edit the local configuration file and enter the following user data.
    • /etc/gigamon-cloud.conf is the local configuration file in Linux platform.
    • C:\ProgramData\gvtap-agent\gigamon-cloud.conf is the local configuration file in Windows platform.

    Registration:
    	groupName: <Monitoring Domain Name>
    	subGroupName: <Connection Name>
    	user: orchestration
    	password: orchestration123A!
    	remoteIP: <IP address of the G-vTAP Controller 1>, 
    		   <IP address of the G-vTAP Controller 2>
    	remotePort: 8891

    Note:  Use only the default user and password details given in the user data.

  4. Restart the G-vTAP Agent service.
    • Linux platform:
      $ sudo service gvtap-agent restart
    • Windows platform: Restart from the Task Manager.

Note:  You can configure more than one G-vTAP Controller for a G-vTAP Agent, so that if one G-vTAP Controller goes down, the G-vTAP Agent registration will happen through another Controller that is active.

The deployed G-vTAP Agent registers with the GigaVUE-FM through the G-vTAP Controller. After successful registration the G-vTAP Agent sends heartbeat messages to GigaVUE-FM every 30 seconds. If one heartbeat is missing, G-vTAP Agent status appears as 'Unhealthy'. If more than five heartbeats fail to reach GigaVUE-FM, GigaVUE‑FM tries to reach the G-vTAP Agent and if that fails as well then GigaVUE‑FM unregisters the G-vTAP Agent and it will be removed from GigaVUE‑FM.