Configure SNMP Traps Notification
GigaVUE-FM sends SNMP Trap notification for the GigaVUE-FM events such as Image Upgrade Status, Backup operation Status to the configured SNMP trap receivers. GigaVUE-FM sends SNMP v2c/v3 trap notifications to specified receivers.
Note: You can configure a maximum of 10 SNMP receivers.
Configuring SNMP traps notification consists of the following steps:
Configure Notification Receivers |
Enable SNMP Trap and Events |
Configure Notification Receivers
To configure a notification receiver follower in a bidirectional clock relationship (formerly slave) and enable the SNMP sever, do the following:
1. | Select Settings > Event Notification > SNMP Server. |
2. | Click Add. The Add SNMP Server page appears. |
3. | Configure the notification receivers by doing the following: |
a. | Enter the IP address of the trap receivers in the Hostname / IP Address field. |
b. | Click in the SNMP Version field and select v2c or v3 from the drop-down list. |
If you select v3, you should enter the User Name and select any of the following Security Level in the drop-down list:
• | noAuthNoPriv – Does not provide authentication or encryption. |
• | AuthNoPriv – Provides authentication but does not provide encryption. When you select this security level, you should also select the required Authentication protocol and should also provide its password. |
• | AuthPriv – Provides both authentication and encryption. When you select this security level, you should also select the required Authentication and Encryption protocols, and should also provide their passwords. |
The following table provides information about the field or fields that should be selected for the above mentioned security levels:
Security Level |
Auth Protocol and Auth Password |
Priv Protocol and Priv Password |
---|---|---|
noAuthNoPriv | No |
No |
AuthNoPriv | Yes. |
No |
AuthPriv | Yes |
Yes |
c. | Enter the server port number in the SNMP Port field. The default port number is 162. |
d. | Enter the community string in the Community field for SNMP Version v2c. For example, public. |
4. | Click Save. |
Validate SNMP Receiver Configuration
To validate the SNMP Receiver Configuration, do the following:
1. | Select Settings > Event Notification > SNMP Server. |
2. | Select the receiver and clickSend Test SNMP Trap to send a test trap to the selected SNMP receiver. |
Enable SNMP Trap and Events
To enable events for SNMP Server Trap notifications, refer to