Bypass Combo Module Specifications
Refer to Table 1: Internal Transceiver Specifications for Bypass Combo Modules and Table 2: Loss Summary per Bypass Combo Modules for specifications for bypass combo modules, including internal transceiver specifications and loss summaries.
Type |
@ |
Operating Wavelength (nm) |
Cable Type |
Max Fiber Length |
Max Receiver Sensitivity |
Insertion Loss (dB) |
||
|
Min |
Typical |
Max |
LC to LC or Port to Port |
||||
BPS-HC0-D25A4GSX/SR 50/125 |
1Gb |
840 |
850 |
860 |
LC |
550m |
-17 |
2 |
10Gb |
840 |
850 |
860 |
LC |
82m |
-11.1 |
2 |
|
BPS-HC0-D25B4GSX/SR 62.5/125 |
1Gb |
840 |
850 |
860 |
LC |
275m |
-17 |
2 |
10Gb |
840 |
850 |
860 |
LC |
33m |
-11.1 |
2 |
|
BPS-HC0-D35C4GLX/LR |
1Gb |
1260 |
1310 |
1355 |
LC |
10km |
-19 |
2 |
10Gb |
1260 |
1310 |
1355 |
LC |
10km |
-12.6 |
2 |
|
BPS-HC0-Q25A28SR4 50/125 |
40Gb |
840 |
850 |
860 |
MPO/MTP |
100m |
-13 |
1 |