Intrabuilding or Intra-connection

WARNING: The intra-building ports:

■   BNC Coaxial PPS
■   RJ45: PTP-1588, Management port, Console port, Stack port
■   RJ45: 10/100/1000 ports: G1 - G4
■   1G/10G SFP+: X1 - X12
■   TAP-HC1-G10040
o   TAP 1G Copper 4 pairs: G1 - G8
■   BPS-HC1-D25A24
o   1G/10G SFP/SFP+: X1 - X4
o   BPS SX/SR (50/125μm) 2 pairs: X5 - X8
■   PRT-HC1-X12
o   1G/10G SFP/SFP+: X1 - X12
■   P/S port on rear of chassis: (Reserved for future use)
■   PRT-HC1-Q04x08
o   40G QSFP+: Q1-Q4
o   1G/10G SFP /SFP+ : X1- X8

GigaVUE‑HC1 equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.