Utilization Alarm/SNMP Notification Generation
Utilization alarms are written to syslog and forwarded to all SNMP management stations configured as notification destinations. For SNMP notifications to be generated, forwarded, and displayed correctly in your SNMP management station, all of the following must be true:
Requirement |
Description |
SNMP Enabled |
Use the snmp-server enable options to turn on the node’s SNMP functionality and enable notifications. |
SNMP Destinations Configured |
Use the snmp-server host options in the CLI to specify the IP addresses for SNMP notification destinations. |
SNMP Notifications Enabled for Utilization Alarms |
Use the portutilization argument for the snmp-server notify event command to enable high utilization notifications. For example: (config) # snmp-server notify event portutilization Use the lowportutilization argument for the snmp-server notify event command to enable low utilization notifications. For example: (config) # snmp-server notify event lowportutilization Refer to Configure Port Utilization Thresholds and Notifications. |
GigaVUE MIB Compiled at Management Station |
You can obtain Gigamon’s latest private MIB file by contacting support@gigamon.com. |
Refer to Use SNMP for information on configuring the GigaVUE H Series node’s SNMP features.