Module Numbering

Modules use standard conventions for identifying network/tool ports, both on the modules themselves, as well as in the CLI:

100Gb Ports

Numbered with a leading C. For example, the PRT-HC0-C02 includes 100Gb ports C1 and C2.

40Gb Ports

Numbered with a leading Q. For example, the PRT-HC0-Q06 includes 40Gb ports Q1 to Q6.

10Gb Ports

Numbered with a leading X. For example, the PRT-HC0-X24 includes 10Gb/1Gb ports X1 to X24, the bypass combo modules include 10Gb ports X1 to X16.

1Gb Ports

Numbered with a leading G.

Note:  When referring to ports in the CLI, the format is box ID/slot ID/port ID. For example, 1/1/x6 refers to box 1, slot 1, port X6.

GigaVUE-HC2: Slots (bays) are numbered 1-4 from left upper, left lower, right upper to right lower.

Note:  The port labels on the module faceplate use upper-case C, Q, X, and G characters to identify ports. However, the CLI uses lowercase notation to refer to ports (for example, c1, q1, x1, and g1).