pld

Required Command-Line Mode = Configure

Use the pld command to perform an upgrade of programmable logic devices (PLDs) such as field programmable gate arrays (FPGAs) on GigaVUE-HC3 nodes. The following components have an FPGA:

PRT-HC3-X24 module
PRT-HC3-C08Q08 module
PRT-HC3-C16 module
SMT-HC3-C05 module
BPS-HC3-C25F2G module
BPS-HC3-Q35C2G module
BPS-HC3-C35C2G module
control card (also referred to as the main board)

FPGA images are bundled with the software image and upgraded with the software image upgrade, however, the pld command provides the ability to upgrade each FPGA individually. Refer to image for information on downloading the software image using the image fetch command.

After a PLD upgrade, the node must be hard reloaded. This is also known as a hard power recycle.

Issue the show pld command to display the PLDs that need to be upgraded, then only upgrade those.

The pld command has the following syntax:

pld
   upgrade slot <slot ID>

The following table describes the arguments for the pld command:

Argument

Description

upgrade slot <slot ID>

Upgrades the PLD image in the specified slot.

For example:

(config) # pld upgrade slot 2

To upgrade the PLD image on the control card:

(config) # pld upgrade slot cc1

Related Commands

The following table summarizes other commands related to the pld command:

Task

Command

Displays information about PLDs, such as, the current revision, and if an upgrade is needed or not.

show pld

Displays information about PLDs for a specific slot ID.

show pld slot 2